6.8 MACHINE PERSONALITY SETTINGS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-1. Personality Ranges/Defaults
FUNCTION PERSONALITY RANGE DEFAULTS - 600S
DRIVE ACCELeration 0.1s to 5.0s 2.0
DECELeration 0.1s to 3.0s 2.0
Forward MINimum speed 0 to 35% 4
Forward MAXimum speed 0 to 100% 35
REVerse MINimum speed 0 to 35% 4
REVerse MAXimum speed 0 to 100% 35
ELEVATED MAXimum speed 0 to 50% 15
CREEP MAXimum speed 0 to 50% 25
Engine RPM 800 to 2900 1800
TOWER LIFT ACCELeration 0.1 to 5.0 N/A
DECELeration 0.1 to 3.0 N/A
MlNimum UP speed 0 to 60% N/A
MAXimum UP speed 0 to 100% N/A
MINimum DOWN speed 0 to 60% N/A
MAXimum DOWN speed 0 to 100% N/A
Engine RPM 800 to 2900 N/A
UPPER LIFT ACCELeration 0.1 to 5.0 2.0
DECELeration 0.1 to 3.0 0.7
MlNimum UP speed 0 to 60% 40
MAXimum UP speed 0 to 100% 80
CREEP Maximum UP speed 0 to 65% 55
MINimum DOWN speed 0 to 60% 40
MAXimum DOWN speed 0 to 100% 70
CREEP maximum DOWN speed 0 to 75% 55
Engine RPM 800 to 2900 1800