Service Manual

SECTION 6 - JLG CONTROL SYSTEM
6-32 – JLG Lift – 3121202
GLOW PLUG:
5
0
1
2
NO GLOW PLUGS: No glow plugs installed.
W/O STARTER LOCK: Automatic pre-glow time determined by ambient air temperature;
engine start can be attempted at any time during pre-glow.
W/ STARTER LOCK: Automatic pre-glow time determined by ambient air temperature;
engine start is NOT permitted until pre-glow is finished.
1
ENGINE SHUTDOWN:
6
0
1
DISABLED: No engine shutdown.
ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C or the
oil pressure is less than 8 psi.
1
TILT:
7*
* Certain market selections
will limit tilt options.
1
2
3
4
5
5 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 5 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 4 degrees and above elevation; also reduces drive speed to creep.
3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 3 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when
tilted more than 4 degrees and above elevation; also disallows tower lift up, tower tele-
scope out, drive, main telescope out and main lift up.
3 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when
tilted more than 3 degrees and above elevation; also disallows tower lift up, tower tele-
scope out, drive, main telescope out and main lift up.
Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and
will sound the platform alarm when the machine is also above elevation.
1
JIB:
8*
* Only visible under certain
model selections
0
1
NO: No jib installed.
YES: Jib installed which has up and down movements only.
0
4 WHEEL STEER:
9*
* Only visible under certain
model selections.
0
1
NO: No four-wheel steer installed.
YES: Four-wheel steer installed.
0
SOFT TOUCH:
10*
* Only visible under certain
model selections.
0
1
NO: No soft touch system installed.
YES: Soft touch system installed.
0
GEN SET/WELDER:
11
0
1
NO: No generator installed.
BELT DRIVE: Belt driven setup.
0
Table 6-3. Machine Configuration Programming Information Prior to Software Version P5.3
Configuration Digit Number Description Default Number