SECTION 6 - JLG CONTROL SYSTEM
6-32 – JLG Lift – 3120840
5
(Tilt Switch)
1
2
3
4
5
5 degree-reduces the maximum speed of all boom functions to creep when tilted and
above elevation.
Reduces drive speed to creep when tilted.
ANSI (US); ANSI (EXPORT); CSA; JAPAN –All Models
1350/1200SJP ALL MARKETS
4 degree-reduces the maximum speed of all boom functions to creep when tilted and
above elevation. Reduces drive speed to creep when tilted.
CE; AUSTRALIA – 400S, 450, & 800S
3 degree-reduces the maximum speed of all boom
functions to creep when tilted and above elevation. Reduces drive speed to creep when
tilted.
CE; AUSTRALIA – 600, 601, 740AJ, & 800 A
4 degree - reduces the maximum speed of all boom functions to creep when tilted and
above elevation and disallows tower lift up, drive, upper telescope out, and upper lift up.
3 degree - reduces the maximum speed of all boom functions to creep when tilted and
above elevation and disallows tower lift up, drive, upper telescope out, and upper lift up.
Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and
will sound the platform alarm when the machine is tilted and above elevation.
1
6
(Tower Lift)
0
1
No Tower Lift Installed
Yes
0
7
(Tower Tele)
0
1
No Tower Telescope Installed
Yes
0
8
(Jib)
0
1
2
No JIB installed.
JIB installed which has up and down movements only.
JIB installed which has up and down movements and side to side movements.
0
9
(4WS)
0
1
No Four-Wheel Steer installed.
Yes
0
10
(Soft Touch System)
0
1
No Soft Touch System Installed
Yes
0
11
(Gen Set/ Welder)
0
1
2
No Generator Installed
Belt Driven
Hydraulic Driven
0
12
(Head and Tail Lights)
0
1
No Head and Tail Lights Installed
Yes
0
Table 6-4. Machine Configuration Programming Information
Configuration Digit Number Description Default Number