Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
3120840 – JLG Lift – 6-33
13
(Broken Cable Switch)
0
1
No Broken Cable Switch Installed
Yes
0
14
(Load Sensor)
0
1
2
3
4
No Load Sensor installed - (DOM - STD)
Functions in Creep, Overload Lamp Lit, Platform Alarm Beeps (5 sec. ON, 2 sec OFF)
All functions cutout, flash overload light (500mS on, 500mS off), Platform Alarm beeps (5
sec ON, 2 sec OFF) - (CE - STD)
All functions cutout, Overload Lamp Lit, Platform Alarm Beeps (5 sec ON, 2 sec OFF)
Special = Functions in Creep, Overload Lamp Lit, Platform Alarm Beeps (5 sec ON, 2 sec
OFF), disables Upper Telescope Out & Upper Lift Up
0
15*
(Load Sensor)
(*Only visible if Load Sensor
Menu selection is not 0)
0
1
1 on rotator - Use the on-board load sensor for all models except those which use the Lev-
eling Platform Module
4 under platform - Use the EIM
0
16
(Function
Cutout)
0
1
2
3
No Drive Cutout - (DOM - STD)
Boom function cutout while driving above elevation. (CE - STD)
Drive Cutout above elevation
Drive Cutout above elevation and tilted
0
17
(Ground Alarm)
0
1
2
3
No ground alarm installed.
Travel alarm- Sounds when the drive function is active. Option
Descent Alarm- Sounds when either lift down is active. Option
Motion alarm- Sounds when any function is active. Option
0
18
(Tower Prox Switches)
0
1
No Tower Prox Switches Installed
Tower Prox Switches Installed - 450A,510, 600A, 740AJ, 800A
0
19
(Drive)
0
1
4 Wheel Drive
2 Wheel Drive
20*
(Flywheel Teeth)
(*Only visible if a Deutz
engine is selected)
0
1
133 Teeth (F3M Prior to 11/16/01; F4M1011 Prior to 1/1/02)
110 Teeth (Deutz 2011, F3M after 11/16/01; F4M 1011 after 1/1/02
4150364-9
Table 6-4. Machine Configuration Programming Information
Configuration Digit Number Description Default Number