Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
3120840 – JLG Lift – 6-39
NO ALTERNATOR OUTPUT 4 3 CLEARS WHEN FAULT IS REMOVED
OIL PRESSURE LOW 4 3 CLEARS WHEN FAULT IS REMOVED
485 COMMUNICATIONS LOST 4 3 CLEARS WHEN FAULT IS REMOVED
CAN BUS FAILURE 6 6 CLEARS WHEN FAULT IS REMOVED
LOAD SENSOR NOT CALIBRATED 9 9 CLEARS WHEN FAULT IS REMOVED
TILT SENSOR NOT CALIBRATED 9 9 CLEARS WHEN FAULT IS REMOVED
EEPROM FAILURE - CHECK ALL SETTINGS 9 9 REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
PLATFORM MODULE FAILURE: HWFS CODE 1 9 9 CLEARS WHEN FAULT IS REMOVED
GROUND MODULE FAILURE: HWFS CODE 1 9 9 CLEARS WHEN FAULT IS REMOVED
Ta b l e 6 - 5. F a u lt C o d e Li s t i n g
HELP MESSAGE FAULT FAULT REMOVAL