Service Manual User guide

SECTION 5 - JLG CONTROL SYSTEM
3121322 – JLG Lift – 5-7
* = This input is only necessary to establish output on J1/2. after the output J1/2 is established input J8/8 is not a necessity.
# = J1/10 output is cut with a momentary lift input and reset with a J1/2 input, or recycling power.
& = 7.5V signal which is level input from sensors.
(1)-) = This input is only necessary to establish this output, after the output is established the input is not necessary.
Table 5-5. NIVOLUX Circuit Board
Input Signal
S2.5M (Fast Drive Available)
RPM (Complex Out)
Lift (From Complex Out)
Lower (From Plat Down LS)
+VS (k VS)
X- Leveling (<7.5V)
X+ Leveling (>7.5V)
Y- Leveling (<7.5V)
Y+ Leveling (>7.5V)
24V (From Jacks Select Sw - Off)
24V (from P Switch or K1)
Output Signal
J8/2
J8/3
J8/6
J8/8
J8/9
J5/3
J5/3
J6/3
J6/3
J10/2
J1/2
RPM (to Deutz box & PNP) Lift wth NIVOLUX J8/4 1 1
RPM (to Deutz box & PNP) Lift wthout NIVOLUX J8/4
1 1 1 1
RPM (to Deutz box & PNP) Lowering J8/4
1 1
Lift Valve J8/7 1 1 1
Drive OK with NIVOLUX J8/10 0 (1)* 1 0 1
Drive OK without NIVOUX J8/10
1 1 1
Front Left IN J7/1 1 1 0
Front Left OUT during leveling J7/2 1 1 1 1 0
Front Left OUT establishing ground pressure J7/2
1 1 & & & & 0 0
Front Right IN J7/4 1 1 0
Front Right OUT during leveling J7/5 1 1 1 1 0
Front Right OUT establishing ground pressure J7/5
1 1 & & & & 0 0
Rear Right IN J7/7 1 1 0
Rear Right OUT during leveling J7/8 1 1 1 1 0
Rear Right OUT establishing ground pressure J7/8
1 1 & & & & 0 0
Rear Left IN J7/10 1 1 0
Rear Left OUT during leveling J7/11 1 1 1 1 0
Rear Left OUT establishing ground pressure J7/11
1 1 & & & & 0 0
X Supply (15V) J5/1 15V Output with Board Power On
Y Supply (15V) J6/1 15V Output with Board Power On
24V (to P Switch and K1 23/24 contacts) J1/1 24V Output with Board Power On
24V (to Jack Select Switch) with NIVOLUX J10/1
(1#) 1 0
24V (to Jack Select Switch) without NIVOLUX J10/1 1 1
LED Left High D42
(1)-) 1 0
LED Right High D43
(1)-) 1 0
LED Front High D44
(1)-) 1 0
LED Rear High D45
(1)-) 1 0
LED No Drive (on) D54
(1)-) 0
Board Power
Ground J8/11
Vs (24V) J8/1