User Manual

9.63
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
Electrical System
BOOM ANGLE
SENSOR – NOT
RESPONDING
2346 1 Di splay the fixed boom angle value
of ‘99’ on the operator’s cabin
display.
Temporaril y assign a fixed boom
angle value of 99×.
Disallow boom angle sensor
calibration (“BOOM ANGLE:
CALIBRATION FAIL”).
Ignore all hydraulic function
requests from the platform module.
Deactivate and inhibit the Lift Up
output if the pl atform is detected as
attached or PLATFORM MODE is
the current active mode; otherwise,
derate the MAX LIFT UP in the
PERSONALITIES menu screen by
the LIFT UP DERATE value in the
Constant Data tables.
J2-11 Main Lift Up Valve or J2-22
Main Lift Down Valve are active
operating at a current of at l east 900
mA for a period of 4 seconds with
an ENGINE RUNNING condition
and no appreciable change set at
0.5 degrees (adjustable in
Constant Data) in the value at this
input. (Note, this fault will not be
report during boom angle sensor
calibration.)
Power cycled.
Message Fault
Code
Indicators Other Actions Taken Trigger for Fault Latch Until