User Manual

Electrical System
9.66
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
ERRATIC
PLATFORM
COUPLED SIGNAL
2385 1 The platform will be considered
coupled.
The UGM detects three signal
transitions on J3-13 within a 5
second period.
Power cyc led.
LOSS OF
PLATFORM
COUPLED SIGNAL
2386 1 N/A The CABIN STATION is active and
a MARKET configuration of
AUSTRALIA exists and J3-13
Platform Coupled input is LOW and
J1-21 Platform Attached input is
LOW or valid platform module CAN
bus messages are being
continuously received by the UGM
or “ERRAC T IC PL ATFORM
ATTACHED SIGNAL” fault exists.
Power cyc led.
FUNCTION
PREVENTED
25XXX
MODEL CHANGED
HYDRAULICS
SUSPENDED –
CYCLE EMS
259 1 Deactivate and inhibit all hydraulic
function operation.
J2-26 Engage Start er output will be
deactivated and engine start will
not be permitted.
The MODEL selection on the
Analyzer was changed from its
previous setting.
Power cyc led.
FUNCTIONS
LOCKED OUT
CONSTANT DATA
VERSION
IMPROPER
2520 1 Deactivate and inhibit all hydraulic
function operation.
J2-26 Engage Start er output will be
deactivated and engine start will
not be permitted.
The Constant Data code version is
not up to date / compatible wit h the
current machine Application code.
Proper
Constant
Version is
loaded and
power is
cycled.
ENGIN E START
PREVENTED
PARK BRAKE NOT
SET
2525 1 J2-26 Engage Starter output will be
deactivated and engine start will
not be permitted.
The CABIN STATION is active and
J4-8 Engine Start input is HIGH and
J4-5 Park Brake is LOW (not set).
J4-5 Park
Brake is HIGH
(set).
BOOM EXTENDED
SWITCH
CONFLICTING
STATE
2526 1 N/A J7-8 Boom Extension Limit input is
LOW, the feature is enabled in the
MACHINE SET UP menu, and the
J3-8 Boom Retracted input is HIGH.
Power cyc led.
EXCESSIVE BOOM
ANGLE FOR
HYDRAULIC QUICK
CONNECT
OPERATION
2527 1 Not activate outputs J2-9 Auxiliary
Function-A Valve or J2-20 Auxiliary
Function-B Valve.
If hydraulic quick connect feature is
configured in the MACHINE SETUP
menu and the boom angle sensor
reading is 10° and the boom angle
sensor has successfully completed
a calibration and a hydraulic quick
connect function request is
detected.
J7-35
Hydraulic
Quick
Connect ON
is LOW and
J3-10
Hydraulic
Quick
Connect OFF
is HIGH.
Message Fault
Code
Indicators Other Actions Taken Tri gge r for Fault Latch Until