User Manual

Electrical System
9.72
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
HYDRAULIC QUICK
CONNECT SELECT
OPEN CIRCUIT
33204 1 Deactivate output J1-23 Hydraulic
Quick Connect Select.
If hydraulic quick connect feature is
configured in the MACHINE SETUP
menu and the UGM detects an
open circuit at this output.
Power cyc led.
HYDRAULIC QUICK
CONNECT SELECT
– SHORT TO
BATTERY
33205 1 Deactivate output J1-23 Hydraulic
Quick Connect Select.
Deactivate output J2-9 Auxiliary
Function-A Valve.
Deactivate output J2-20 Auxiliary
Function-B Valve.
If hydraulic quick connect feature is
configured in the MACHINE SETUP
menu and the UGM detects a short
to battery at this output.
Power cyc led.
HYDRAULIC QUICK
CONNECT SELECT
– SHORT TO
GROUND
33206 1 Deactivate output J1-23 Hydraulic
Quick Connect Select.
Deactivate output J2-9 Auxiliary
Function-A Valve.
Deactivate output J2-20 Auxiliary
Function-B Valve.
If hydraulic quick connect feature is
configured in the MACHINE SETUP
menu and the UGM detects a short
to ground at t his output.
Power cyc led.
HORN –
OPEN CIRCUIT
33207 1 Deactivate output J2-2 Horn. The UGM detect s an open circuit at
this output.
Power cyc led.
HORN – SHOR T TO
BATTERY
33208 1 Deactivate output J2-2 Horn. The UGM detects a short to battery
at this output.
Power cyc led.
HORN – SHOR T TO
GROUND
33209 1 Deactivate output J2-2 Horn. The UGM detects a short to ground
at this output.
Power cyc led.
REVERSE ALARM
AND LIGHTS –
OPEN CIRCUIT
33210 1 Deact ivate output J1-1 Reverse
Alarm and Lights.
The UGM detects an open circuit at
this output.
Power cyc led.
REVERSE ALARM
AND LIGHTS –
SHORT TO
BATTERY
33211 1 Deactivate output J1-1 Reverse
Alarm and Lights.
The UGM detects a short to battery
at this output.
Power cyc led.
REVERSE ALARM
AND LIGHTS –
SHORT TO
GROUND
33212 1 Deact ivate output J1-1 Reverse
Alarm and Lights.
The UGM detects a short to ground
at this output.
Power cyc led.
DUMP VALVE –
OPEN CIRCUIT
33213 1 Deactivate output J2-13 Dump
Valve.
The platform option is configured
and the UGM detects an open
circuit at this output.
Power cyc led.
Message Fault
Code
Indicators Other Actions Taken Tri gge r for Fault Latch Until