User Manual

9.73
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
Electrical System
DUMP VALVE –
SHORT TO
BATTERY
33214 1 Deactivate output J2-13 Dump
Valve.
Deactivate output J2-3 Right
Stabilizer Up Valve.
Deactivate output J2-5 Frame Level
Right Val ve.
Deactivate output J2-7 Frame Level
Left Valve.
Deactivate output J2-8 Fork Tilt Up
Valve.
Deactivate output J2-9 Auxiliary
Function-A Valve.
Deactivate output J2-10 Left
Stabilizer Up Valve.
Deactivate output J2-11 Main Lift
Up Valve.
Deactivate output J2-15 Right
Stabilizer Down Valve.
Deactivate output J2-19 Fork Tilt
Down Valve.
Deactivate output J2-20 Auxiliary
Function-B Valve.
Deactivate output J2-21 Left
Stabilizer Down Valve.
Deactivate output J2-22 Main Lift
Down Valve.
Deactivate output J2-34 Main
Telescope In Valve.
Deactivate output J2-35 Main
Telescope Out Valve.
Deactivate output J1-3 Stabilizer
and Frame Level Speed Valve
(if applicable).
The platform option is configured
and the UGM detects a short to
battery at this output.
Power cycled.
DUMP VALVE –
SHORT TO
GROUND
33215 1 Deactivate output J2-13 Dump
Valve.
The platform option is configured
and the UGM detects a short to
ground at this output.
Power cycled.
AUXILIARY
FUNCTION SELECT
– OPEN CIRCUIT
33216 1 Deactivate output J2-1 Auxiliary
Function Select.
The CAT brand is configured for the
UGM, the PLATFORM STATION is
not
active, and the UGM detects an
open circuit at this output.
Power cycled.
AUXILIARY
FUNCTION SELECT
– SHORT TO
BATTERY
33217 1 Deactivate output J2-1 Auxiliary
Function Select.
Deactivate output J2-9 Auxiliary
Function-A Valve.
Deactivate output J2-20 Auxiliary
Function-B Valve.
The CAT brand is configured for the
UGM and the UGM detects a short
to battery at this output.
Power cycled.
AUXILIARY
FUNCTION SELECT
– SHORT TO
GROUND
33218 1 Deactivate output J2-1 Auxiliary
Function Select.
Deactivate output J2-9 Auxiliary
Function-A Valve.
Deactivate output J2-20 Auxiliary
Function-B Valve.
The CAT brand is configured for the
UGM and the UGM detects a short
to ground at this output.
Power cycled.
Message Fault
Code
Indicators Other Actions Taken Trigger for Fault Latch Until