Electrical System
9.74
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
AUXILIARY
ELECTRICS – OPEN
CIRCUIT
33219 1 Deactivate output J2-1 Auxiliary
Electrics.
The JLG brand is configured for the
UGM, the PLATFORM STATION is
not
active, and the UGM detects an
open circuit at this output.
Power cyc led.
AUXILIARY
ELECTRICS –
SHORT TO
BATTERY
33220 1 Deactivate output J2-1 Auxiliary
Electrics.
The JLG brand is configured for the
UGM and the UGM detects a short
to battery at this output.
Power cyc led.
AUXILIARY
ELECTRICS –
SHORT TO
GROUND
33221 1 Deactivate output J2-1 Auxiliary
Electrics.
The JLG brand is configured for the
UGM and the PLA TFORM ST ATION
is not
active and the UGM detects a
short to ground at this output.
Power cyc led.
LEFT STABILIZER
DOWN VALVE –
OPEN CIRCUIT
33222 1 Deact ivate output J2-15 Right
Stabilizer Down V alve.
Deactivate output J2-21 Left
Stabilizer Down V alve.
The stabilizers are configured in the
MACHINE SETUP menu and the
UGM detects an open circuit at t his
output.
Power cyc led.
LEFT STABILIZER
DOWN VALVE –
SHORT TO
BATTERY
33223 1 Deact ivate output J2-3 Right
Stabilizer Up Valve.
Deactivate output J2-15 Right
Stabilizer Down V alve.
Deactivate output J2-10 Left
Stabilizer Up Valve.
Deactivate output J2-21 Left
Stabilizer Down V alve.
Deactivate and inhibit out put J1-3,
(Frame Leveling and Stabilizers will
be cutout).
The stabilizers are configured in the
MACHINE SETUP menu and the
UGM detects a short to battery at
this output.
Power cyc led.
LEFT STABILIZER
DOWN VALVE –
SHORT TO
GROUND
33224 1 Deact ivate output J2-15 Right
Stabilizer Down V alve.
Deactivate output J2-21 Left
Stabilizer Down V alve.
The stabilizers are configured in the
MACHINE SETUP menu and the
UGM detects a short to ground at
this output.
Power cyc led.
LEFT STABILIZER
UP VALVE – OPEN
CIRCUIT
33225 1 Deact ivate output J2-3 Right
Stabilizer Up Valve.
Deactivate output J2-15 Right
Stabilizer Down V alve.
Deactivate output J2-10 Left
Stabilizer Up Valve.
Deactivate output J2-21 Left
Stabilizer Down V alve.
The stabilizers are configured in the
MACHINE SETUP menu and the
UGM detects an open circuit at t his
output.
Power cyc led.
LEFT STABILIZER
UP VALVE – SHORT
TO BATTERY
33226 1 Deact ivate output J2-3 Right
Stabilizer Up Valve.
Deactivate output J2-15 Right
Stabilizer Down V alve.
Deactivate output J2-10 Left
Stabilizer Up Valve.
Deactivate output J2-21 Left
Stabilizer Down V alve.
Deactivate and inhibit output
J1-3, (Frame Leveling and
Stabilizers will be cutout).
The stabilizers are configured in the
MACHINE SETUP menu and the
UGM detects a short to battery at
this output.
Power cyc led.
Message Fault
Code
Indicators Other Actions Taken Tri gge r for Fault Latch Until