User Manual

9.77
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
Electrical System
TRA N SMISSION C
COIL – SHORT TO
GROUND
33242 1 Deactivate output J1-10
Transmission C Control Coil.
3
rd
, 2
nd
, and 1
st
will be the only
available gear selections.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and a
GEAR SELECTION of 4F/3R is
configured and the UGM detects a
short to ground at this output.
Power cycled.
TRA N SMISSION B
COIL –
OPEN CIRCUIT
33243 1 Deactivate output J2-32
Transmission B Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and
the UGM detects an open circuit at
this output.
Power cycled.
TRA N SMISSION B
COIL – SHORT TO
BATTERY
33244 1 Deactivate output J2-32
Transmission B Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and
the UGM detects a short to battery
at this output.
Power cycled.
TRA N SMISSION B
COIL – SHORT TO
GROUND
33245 1 Deactivate output J2-32
Transmission B Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and
the UGM detects a short to ground
at this output.
Power cycled.
TRANSMISSION
REVERSE COIL –
OPEN CIRCUIT
33246 1 Deactivate output J2-32
Transmission Reverse Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
HYDROSTATIC is configured and
the UGM detects an open circuit at
this output.
Power cycled.
TRANSMISSION
REVERSE COIL –
SHORT TO
BATTERY
33247 1 Deactivate output J2-32
Transmission Reverse Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
HYDROSTATIC is configured and
the UGM detects a short to battery
at this output.
Power cycled.
TRANSMISSION
REVERSE COIL –
SHORT TO
GROUND
33248 1 Deactivate output J2-32
Transmission Reverse Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
HYDROSTATIC is configured and
the UGM detects a short to ground
at this output.
Power cycled.
TRA N SMISSION A
COIL –
OPEN CIRCUIT
33249 1 Deactivate output J2-33
Transmission A Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and
the UGM detects an open circuit at
this output.
Pow
er cycled.
TRA N SMISSION A
COIL – SHORT TO
BATTERY
33250 1 Deactivate output J2-33
Transmission A Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configurat ion of
POWERSHIFT is configured and
the UGM detects a short to battery
at this output.
Power cycled.
Message Fault
Code
Indicators Other Actions Taken Trigger for Fault Latch Until