User Manual

Electrical System
9.92
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
LSS CELL #1
ERROR
821 1, 14 Deactivate and inhibit the Lift Up
output.
Deactivate and inhibit the Lift Down
output.
Deactivate and inhibit the
Telescope Out output.
Deactivate and inhibit the
Te lescope In output.
Deactivate and inhibit the Platform
Rotate Left output.
Deactivate and inhibit the Platform
Rotate Right output.
Deactivate and inhibit the Platform
Level Up output.
Deactivate and inhibit the Platform
Level Down output .
Deactivate platform module output
J2-19 Function Enable Relay.
Display the platform overloaded
screen on the cabin’s LCD.
The UGM has detected the
PLATFORM STA TION is active and
the PLATFORM OPTION is
ENABLED and a platform is
detected as attached and the LSS
module is reporting a error with
regard to load cell #1.
Power cyc led.
LSS CELL #2
ERROR
822 1, 14 Deactivate and inhibit the Lift Up
output.
Deactivate and inhibit the Lift Down
output.
Deactivate and inhibit the
Telescope Out output.
Deactivate and inhibit the
Te lescope In output.
Deactivate and inhibit the Platform
Rotate Left output.
Deactivate and inhibit the Platform
Rotate Right output.
Deactivate and inhibit the Platform
Level Up output.
Deactivate and inhibit the Platform
Level Down output .
Deactivate platform module output
J2-19 Function Enable Relay.
Display the platform overloaded
screen on the cabin’s LCD.
The UGM has detected the
PLATFORM STA TION is active and
the PLATFORM OPTION is
ENABLED and a platform is
detected as attached and the LSS
module is reporting a error with
regard to load cell #2.
Power cyc led.
Message Fault
Code
Indicators Other Actions Taken Tri gge r for Fault Latch Until