User Manual

Electrical System
9.94
L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7
LSS HAS NOT BEEN
CALIBRATED
825 1, 14 Deactivate and inhibit the Lift Up
output.
Deactivate and inhibit the Lift Down
output.
Deactivate and inhibit the
Telescope Out output.
Deactivate and inhibit the
Te lescope In output.
Deactivate and inhibit the Platform
Rotate Left output.
Deactivate and inhibit the Platform
Rotate Right output.
Deactivate and inhibit the Platform
Level Up output.
Deactivate and inhibit the Platform
Level Down output .
Deactivate platform module output
J2-19 Function Enable Relay.
Display the platform overloaded
screen on the cabin’s LCD.
The UGM has detected the
PLATFORM STA TION is active and
the PLATFORM OPTION is
ENABLED and a platform is
detected as attached and the LSS
module calibration has not been
completed.
A valid
calibration of
the LSS
module is
completed or
the LOAD
SENSING
menu screen
is configured
to NONE and
power is
cycled.
PLATFORM FUNC-
TIONS CUTOUT –
PLATFORM
OVERLOADED
829 1, 14 Deactivate and inhibit the Lift Up
output.
Deactivate and inhibit the Lift Down
output.
Deactivate and inhibit the
Telescope Out output.
Deactivate and inhibit the
Te lescope In output.
Deactivate and inhibit the Platform
Rotate Left output.
Deactivate and inhibit the Platform
Rotate Right output.
Deactivate and inhibit the Platform
Level Up output.
Deactivate and inhibit the Platform
Level Down output .
Deactivate platform module output
J2-19 Function Enable Relay when
platform module detects condition if
the UGM fails to report the
condition in 1 second.
Display the platform overloaded
screen on the cabin’s LCD.
When the UGM or platform module
detects an overloaded platform
condition at 110% rated load and
the PLATFORM STATION is
selected and a platform is detected
as attached and the LOAD
SENSING menu screen is
configured as PLATFORM
CUTOUT.
When a rated
load of less
than 110% is
detected for a
period of at
least 3
seconds. (The
system will
then re-enable
J2-19
Function
Enable Relay
and verify the
platform
function
enable switch
is not
engaged
before
operation is
allowed.)
LOAD MOMENT 85XXX
LSI NOT
CALIBRATED
8514 1 Set CAN message bit to permit LSI
System display control of its alarm.
Within 1500ms of system power
ON, the UGM reads a CAN
message from the LSI System
indicating calibration has not
occurred.
The LSI
System CAN
message
which
indicates the
calibration
mode status
changes to
OFF.
Message Fault
Code
Indicators Other Actions Taken Tri gge r for Fault Latch Until