Electrical System
LSI DETECTED BUT
NOT CONFIGURED
8515 1 Inhibit all hydraulic functions.
Set CAN message bit to permi t LSI
System display control of its alarm.
The UGM has detected the CAN
bus LSI system is present on the
machine; however it has not been
configured properly in the
MACHINE SETUP - LOAD
MOMENT me nu se lection.
Use analyzer
and correct
parameter
that is
improperly
configured.
LSI LOAD CELL A –
OUT OF RANGE
8516 1 If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MA RKET
configuration.
Set CAN message bit to permi t LSI
System display control of its alarm.
The LSI System has detected that
Load Cell A is out of range and is
providing a CAN bus message
notification to the UGM.
Power cycle.
LSI LOAD CELL B –
OUT OF RANGE
8517 1 If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MA RKET
configuration.
Set CAN message bit to permi t LSI
System display control of its alarm.
The LSI System has detected that
Load Cell B is out of range and is
providing a CAN bus message
notification to the UGM.
Power cycle.
LSI C UTOUT
OUTPUT – SHORT
TO BATTERY OR
OPEN CIRCUIT
8518 1 If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MA RKET
configuration.
Set CAN message bit to permi t LSI
System display control of its alarm.
The LSI System has detected that
its 100% Cutout digital output has
an short to batt ery or open circuit
condition and is providing a CAN
bus message notification to the
UGM.
Power cycle.
LSI OUT OF
CALIBRATION
8519 1 If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MA RKET
configuration.
Set CAN message bit to permi t LSI
System display control of its alarm.
The UGM LSI-CAN system check
has been performed and the actual
load cell raw counts are not within
+/- 10 counts of the logged
calibrated counts.
The LSI-CAN
system check
is performed
and is
completed
with a pass
condition.
STEERING 86XXX
LOW STEE R ING
PRESSURE
8638 1, 8 N/A J1-35 Steering Pressure is HIGH for
a period of 3 seconds or more and
an ENGINE RUNNING state must
be detected for at least 5 seconds.
Until steer
pressure is
re-estab-
lished (i.e.
J1-35 is LOW
for a period of
3 seconds).
HARDWARE 99X XX
LSS WATCHDOG
RESET
991 1 Power cycle.
(Replace
board)
Message Fault
Code
Indicators Other Actions Taken Trigger for Fault Latch Until