Operator Manual Owner's manual
SECTION 2 - PREPARATION AND INSPECTION
2-2 – JLG Lift – 3121135
2.2 PREPARATION, INSPECTION, AND
MAINTENANCE
The following table covers the periodic machine inspec-
tions and maintenance recommended by JLG Industries,
Inc. Consult local regulations for further requirements for
aerial work platforms. The frequency of inspections and
maintenance must be increased as necessary when the
machine is used in a harsh or hostile environment, if the
machine is used with increased frequency, or if the
machine is used in a severe manner.
IMPORTANT
JLG INDUSTRIES, INC. RECOGNIZES A QUALIFIED JLG
MECHANIC AS A PERSON WHO HAS SUCCESSFULLY COM-
PLETED THE JLG SERVICE TRAINING SCHOOL FOR THE SPE-
CIFIC JLG PRODUCT MODEL.
Table 2-1. Inspection and Maintenance Table
TYPE FREQUENCY
PRIMARY
RESPONSIBILITY
SERVICE
QUALIFICATION
REFERENCE
Pre-Start
Inspection
Before using each day; or
whenever there’s an Operator change.
User or Operator User or Operator Operator and Safety Manual
Pre-Delivery
Inspection
(See Note)
Before each sale, lease, or rental delivery. Owner, Dealer, or User Qualified JLG
Mechanic
Service and Maintenance
Manual and applicable JLG
inspection form
Frequent
Inspection
In service for 3 months or 150 hours, whichever
comes first; or;
Out of service for a period of more than 3 months; or
Purchased used.
Owner, Dealer, or User Qualified JLG
Mechanic
Service and Maintenance
Manual and applicable JLG
inspection form
Annual Machine
Inspection
Annually, no later than 13 months from the date of
prior inspection.
Owner, Dealer, or User Qualified JLG
Mechanic
Service and Maintenance
Manual and applicable JLG
inspection form
Preventative
Maintenance
At intervals as specified in the Service and Mainte-
nance Manual.
Owner, Dealer, or User Qualified JLG
Mechanic
Service and Maintenance
Manual
NOTE: Inspection forms are available from JLG. Use the Service and Maintenance Manual to perform inspections.