Table 3-6.Electrical System - Troubleshooting
TROUBLE PROBABLE CAUSE REMEDY
PLATFORM CONTROLS.
No power to platform controls.
15 Amp self-reset circuit breaker open. Check footswitch to ensure that both switches
are making contact when pedal is depressed.
Repair or replace footswitch as necessary.
Contact block in footswitch malfunctioning. Repair, replace or adjust contact block as
required.
Faulty power circuit wiring. Check wiring continuity. Refer to proper wiring
diagram.
Platform EMS or Ground EMS switch in wrong
position.
Place switch to correct position.
ENGINE ST ARTER SYSTEM (GENERATOR).
Starter will not crank.
Discharged battery or loose battery terminals. Check and charge battery or replace battery as
necessary . Clean and secure battery terminals.
Starter relay faulty or faulty relay connections. Using a test meter, check relay coil terminals for
presence of electrical power and for energization
of relay coil. Also check relay terminals for cor-
rect switching of contacts. Replace relay as nec-
essary.
Malfunctioning starter solenoid or motor. Replace solenoid or motor in accordance with
applicable manufacturers manual.
Malfunctioning manual start switch. Using a test meter, check ignition switch for cor-
rect switching of contacts. Replace switch as
necessary .
Faulty ignition and/or starter circuit wiring. Check wiring continuity. See proper wiring dia-
gram.
Faulty start switch. Replace switch.
INSTRUMENTS AND INDICA TORS.
Travel warning horn inoperative.
Machine set-up incorrect. Adjust control module settings properly .
Damaged wiring in horn circuit. Repair or replace wiring/Run System Test.
Damaged horn. Replace horn.