SECTION 2 - PROCEDURES
2-4 – JLG Lift – 3120884
Lubrication Specifications
Specified lubricants, as recommended by the component
manufacturers, are always the best choice, however,
multi-purpose greases usually have the qualities which
meet a variety of single purpose requirements. Should
any question arise regarding the use of greases in mainte-
nance st ock, consult yo ur loc al supp lier for eval uation.
Refer to Secti on 1 for an explan ation of the lub ricant key
designations appearing in the Lubrication Chart.
2.4 BATTERY MAINTENANCE AND
CHARGING
Battery Maintenance, Quarterly
1. Open battery compartment cover to allow access to
battery terminals and vent caps.
WHEN ADDING WATER TO BATTERIES, ADD WATER UNTIL ELEC-
TROLYTE COVERS PLATES. DO NOT CHARGE BATTERIES
UNLESS ELECTROLYTE COVERS THE PLATES.
NOTE: When add ing di stille d w ater to batteries , non-m etalli c
containers and/or funnels must be used.
To avoid electrolyte overflow, add distilled water to
batteries after charging.
When adding water to the battery, fill only to level
indicated or 9.5 mm above separators.
2. Remove all vent caps and inspect electrolyte level of
each cell. Electrolyte level should be to the ring
approximately one inch from top of battery. Fill bat-
teries with distilled water only. Replace and secure
all vent caps.
3. Remove battery cables from each battery post one
at a time, negative first. Clean cables with acid neu-
tralizing solution (e.g. baking soda and water or
ammonia) and wire brush. Replace cables and/or
cable cl amp bolts as required.
4. Clean battery post with wire brush then re-connect
cable to post. Coat non-contact surfaces with min-
eral grease or petroleum jelly.
5. When all cables and terminal posts have been
cleaned, ensure all cables are properly positioned
and do not get pinched. Close battery compartment
cover.
6. Start hydraulic system and ensure that it functions
properly.
Optional On Board Generator
EXHAUST GAS HAZARD. RUN THE GENERATOR IN A WELL VEN-
TILATED AREA ONLY.
WHEN THE GENERATOR ENABLE CONTROL LOCATED IN THE
PLATFORM CONTROL BOX IS IN THE ON POSITION AND THE
GROUND EMERGENCY STOP SWITCH IS ON (PULLED OUT), THE
GENERATOR WILL START AUTOMATICALLY WHEN THE BAT-
TERIES REACH A LOW-CHARGE STATE, AUTOMATICALLY
CHARGING THE BATTERIES. THE GENERATOR WILL ALSO
AUTOMA TICALLY STAR T IF THE GENE RATOR START BATTERY
IS LOW.