User Manual

SECTION 2 - PROCEDURES
3120884 – JLG Lift – 2-23
4. Place two (2) 3/8"x16NC bolts in threaded holes in
bottom of the actuator. Using a suitable bar, unscrew
the end cap (5). Remove the end cap from the actu-
ator housing (1).
5. Remove the shaft (2) from piston sleeve ( 3) and the
actuator ho us ing (1).
6. Remove piston sleeve (3) from housin g (1).
7. Remove all seals and bearings from grooves. Dis-
card seals.
Inspection
1. Clean all parts thoroughly.
2. Closely inspect all parts for excessive wear, cracks
and chips. Replac e parts as necessary.
NOTE: A small amount of wear in the spline teeth will have
little effect on the actuator strength. New spline sets
are manufactured with a backlash of about 0.005 in.
per mating set. After long service, a backlash of
about 0.015 per set may still be acceptable in most
cases, depending on the required accuracy of the
application.
3. Check the ring gear for wear and weld damage to
the pins.
4. Inspect the cylinder bore for wear and scratches .
Figure 2 - 24. Removing End Cap
Figure 2-2 5. Removing Shaft from Housi ng
Figure 2-26. Removing Sleeve from Hous ing