User Manual

SECTION 2 - PROCEDURES
3120884 – JLG Lift – 2-49
Machine Setup
When a mach ine digit item is selected, pr ess the UP or
DOWN arrow keys to adjust its value, for example:
GROUND ALARM :
2 = DRIVE
The effect of th e machine digit value is dis played along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you
wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.
When selection the machine model to match the size of
the machine, the person ality settings will all default to the
factory recommen de d se t t ing.
NOTE: Refer to Table 2-5, Personality Ranges/Defaults, and
Table 2-6, Machine Setup Descriptions in this Ser-
vice Man u al for the recommended factory settin gs.
NOTE: Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality settings.
There is a setting that JLG strongly recommends that you
do not change. This setting is so noted below:
ELEVATION CUTBACK
CHANGING THIS SETTING MAY ADVERSELY AFFECT THE PER-
FORMANCE OF YOUR MACHINE.
ITS IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING
ELECTRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG IN DUSTRIES INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 52 BAR (750 PSI) AT A
MINIMUM DISTANCE OF 30.5CM (12 INCHES) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.