User Manual

SECTION 2 - PROCEDURES
3120884 – JLG Lift – 2-53
Machine Configuration Programming
Information
NOTE: The following information is to be used when working
with the MACHINE SETUP menu. When confi guring
the machine, the machine configuration must be
completed before any personality settings can be
changed. Changing the personality settings first and
then changing the model number of the machine
configuration will cause the personality settings to
return to default values.
Default settings will be shown in bold type.
1. MODELS (names may change)
1=E300
2=M45; E45
2. TILT SENSO R
When tilted the tilt light is lit ( continuously) and drive
speed is reduced to the creep speed setting
1=5 degree - reduces the maximum speed of all
platform functions to creep when tilted and
above elevation. Reduces drive speed to creep
when tilted. (Domestic/Japan)
2=3 degree - reduces the maximum speed of all
platform functions to creep when tilted and above
elevation. Reduces drive speed to creep when tilted.
(European/Austra lian)
3=3 degree - cuts out drive and reduces functions
to creep speed when active and above elevation.
Reduces drive speed to creep when tilted only.
(Option)
NOTE: Any of the selections above will light the tilt lamp
when a tilted condition occurs and will sound the
platform alarm when the machine is tilted and above
elevation.
3. D R I V E CUT O UT
0=Battery Charger Cutout - cuts out drive when
the battery charger i s plugged in
1= Battery Charger Cutout and Simultaneous Drive
and Boom fun ctions disabled abo ve elevation (Euro-
pean/Au stralia n)
2= Battery Charger Cutout and Drive Cutout above
elevation (Option)
4. FUNCTION CUTOUT LIMIT SWITCH
0= No Functi on Cutout
1= Cuts out all boom functions when switch opens
(Option)
2= Cuts out all functions when the switch opens
(Option)
5. JIB
0=No jib installed
1=Jib installed which has up and down movements
only (Option)
2=Jib installed which has up and down movements
and side to side movements (Option)
6. GROUND ALARM
0= No ground alarm installed
1= Travel Alarm - Sounds when the drive function is
active (Option)
2= Descent Alarm - Sounds when either lift down is
active (Option)
Table 2-6. Machine Setup Descriptions
MODEL NUMBER... Displays/adjusts machine model
NOTE: all personalities reset to default
when model number is altered
TILT ... Displays/adjusts tilt sensor function
DRIVE CUTOUT ... Displays/adjusts drive cutout switch
presence/ function
FUNCTION CUTOUT ... Displays/adjusts function cutout switch
presence/function
JIB. . . Displays/adjusts jib presence
GROUND ALARM... Displays/adjusts ground alarm pres-
ence/ function
PLATFORM ALARM... Displays/adjusts platform alarm pres-
ence/ function
BATTERY MONITOR... Displays/adjusts battery monitor, which
indicates “WATER BATTERIES” after a
number of charge/discharge cycles
Updated 10-7-99