SECTION 2 - PROCEDURES
2-70 – JLG Lift – 3120884
2.25 GENERATOR
NOTE: Throughout the Generator section, the abbreviations
RBS and CTS are used. RBS stands for Rotar y Bat-
tery System, which is the generator system. CTS
stands for Call To St art, which is t he electronic in put s
which signal the generator to start and charge the
batteries.
The generator consists of a drive engine, controller, and
related components.
Alternato r
The alternat or is a brushle ss, DC outpu t alternator. The 3
phase output of the alternator is full wave rectified and
directed to the output terminator.
The output rating is 58 volts DC at 55 amps. Voltage regu-
lation and current limiting is provided by the Engine/Gen-
erator Controller.
The rectifier diodes and output current sensor are located
in the alternator end.
Dynamo and Dyna mo Voltage Regulator
The engine is equipped with a 12 Vo lt, 15 Amp DC output
dynamo.
Dynamo Output Fuse
The dynamo output fuse is used to protect the output of
the dynamo. This fuse is rated at 20 Amps DC, slow blow
and is located on the left side of the engine.
Control Fuse
This fuse provides power to the engine/generator and the
relays for start control, fuel control, and pre-heater. This
fuse is rated at 15 Amps DC and is located on the right
side of the engine.
Start Battery
A 12 volt lead-acid battery is utilized to provide starting
power for the generator and power for the generator con-
trols. This battery is charged by the engine dynamo and
dynamo regulator when the engine is running.
Engine Starter
The engine is equipped with a 12 Volt DC starter. T his
starter pr ovides mechanical pow er to crank th e engine.
Electrical power for the starter is provided by the start bat-
tery. The starter is energized by the start control relay.
St a rt Co ntrol Relay
The start control relay energizes the solenoid of the
engine starter and the pull coil of the engine fuel soleno id .
The start control relay is located on the fuel solenoid
brack et on th e right si de of the en gine. Th e start co ntrol
relay is energized by the engine/genera tor controller.
Fuel Control Relay
The fuel control relay energizes the hold coil of the fuel
solenoid. The fuel control relay is energized by the
engine/g enerator controller.
Fuel Solenoid
The fuel solenoid actuates the run/stop lever of the
engine. This solenoid has a pull and hold coil. The pull coil
is energized by the start control rel ay and the hold coil is
energized by the fuel control relay.
Engin e Oil Temperature Sensor
The engine oil temperature sensor is used to sense t he
temperature of the oil in the sump of the engine. This sen-
sor provides a signal to the engine/ generator controller for
high engine temperature shutdown.
Alternato r Output Current Sensor
The alternato r o utput c urrent s ensor provid es a signal p ro-
portional to the output current of the alternator to the
engine/generator controller. This signal is used by t he
controller to regulate the current output of the alternator.
The output current is regulated at 55 Amps DC. The alter-
nator output current sensor is located inside the rear
cover of the alternator.
Engine Spee d Se nsor
The engine speed sensor provides a signal proportional
to the rotational speed of the eng ine to the eng ine/genera-
tor controller. This sign al i s used by the controller to deter-
mine starter cut-out, overspeed fault, and underspeed
fault. This signal has failsafe protection, if it is not present
at the controller, the unit will fault with a loss of speed sig-
nal indication. The engine speed sensor is located inside
the recoil starter cover at the front of the engine.
Engin e Low Oil Pressure Switch
The engine is eq uipped w ith a low oi l pressure switch . The
switch is closed when the oil pressure is below 14.2 psi (1
Bar).