SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
7-2 – JLG Lift – 3121198
Resistance Measurement
First test meter and leads by touching leads together.
Resistance should read a short circuit (very low resis-
tance)
Circuit power must be turned OFF before testing resis-
tance
Disconnect component from circuit before testing
If meter is not auto ranging, set it to the correct range
(See multimeter’s operation manual)
Use firm contact with meter leads
Continuity Measurement
Some meters require a separate button press to
enable audible continuity testing
Circuit power must be turned OFF before testing conti-
nuity
Disconnect component from circuit before testing
Use firm contact with meter leads
First test meter and leads by touching leads together.
Meter should produce an audible alarm, indicating
continuity
Figure 7-2. Resistance Measurement
Figure 7-3. Continuity Measurement