User Manual
BATTERY CHARGER FAULT CODES
BOOM LIFT MODELS X14J
JLG
150
X14JR0420113
CODE DESCRIPTION STATUS ACTION
8
Internal logic fault. Baery charger stops working.
Contact service dept. or
change product.
13
Communication pro‑
blem with external
memory.
Baery charger stops working.
Contact service dept. or
change product.
19
Internal logic fault. Baery charger stops working.
Contact service dept. or
change product.
242
Error when reading
internal memory on
microcontroller.
Baery charger stops working.
Contact service dept. or
change product.
252
Short‑circuit in bat‑
tery charger output.
Baery charger stops working.
Turn off baery charger
and resolve short‑circuit at
output. If problem persists,
contact service dept. or
change product.
246
Stage 1 ended by
timeout without
reaching control
voltage.
Baery charger stops working.
Make sure baery capacity
is compatible or check that
baery is compliant with
baery charger. If baery
is correct and problem per‑
sists, contact service dept.
241
Problem in CANBUS
communication with
other systems in the
network.
The way this is managed may
change based on different
firmware releases.
Check correct operation of
CANBUS system.