CODE DESCRIPTION STATUS ACTION
248
Temperature inside
baery charger too
high.
If internal temperature exceeds
80°C, baery charger reduces
power to 80%, while it stops
operating altogether if internal
temperature exceeds 90°C. Bat‑
tery charger starts at full
power again when internal
temperature falls below 70°C.
249
Baery temperature
too high.
If temperature exceeds 55°C or
is less than ‑20°C, baery char‑
ger stops working.
When baery temperature falls
below 45°C or exceeds ‑10°C
baery charger resumes nor‑
mal operation.
251
Power failure
detected.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, check
baery charger mains
power supply.
242
Error when reading
internal memory on
microcontroller.
Baery charger stops working.
Contact service dept. or
change product.
18
Extended shutdown
or power failure.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present or
aer restarting.
If problem is a power failu‑
re, check baery charger
mains power supply.
245
Abnormal current
draw in primary sec‑
tion.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, contact
service dept. or change
product.
240
Digital input is open
and managed as
hardware start‑stop.
Baery charger stops charging
until digital input closes.
Close digital input.