User Manual
151
BOOM LIFT MODELS X14J
JLG
X14JR0420113
CODE DESCRIPTION STATUS ACTION
248
Temperature inside
baery charger too
high.
If internal temperature exceeds
80°C, baery charger reduces
power to 80%, while it stops
operating altogether if internal
temperature exceeds 90°C. Bat‑
tery charger starts at full
power again when internal
temperature falls below 70°C.
249
Baery temperature
too high.
If temperature exceeds 55°C or
is less than ‑20°C, baery char‑
ger stops working.
When baery temperature falls
below 45°C or exceeds ‑10°C
baery charger resumes nor‑
mal operation.
251
Power failure
detected.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, check
baery charger mains
power supply.
242
Error when reading
internal memory on
microcontroller.
Baery charger stops working.
Contact service dept. or
change product.
18
Extended shutdown
or power failure.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present or
aer restarting.
If problem is a power failu‑
re, check baery charger
mains power supply.
245
Abnormal current
draw in primary sec‑
tion.
Baery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.
If problem persists, contact
service dept. or change
product.
240
Digital input is open
and managed as
hardware start‑stop.
Baery charger stops charging
until digital input closes.
Close digital input.