SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3128791 – JLG Lift – 6-19
GENERATOR ON or OFF depending on whether, the engine is ON or
OFF.
EMERG. COMM ON position indicates the emergency buttons are acti-
vated.
MICROROPES ON position indicates both cables are working.
START M. TE ON position indicates the engine start button (from
ground) is pressed.
MOTOR TEMP. OFF position with the engine running indicates the alarm
is activated.
MOTOR PRESS. ON position with the engine running indicates the alarm
is activated.
START M. EL ON position indicates the remote control from ground is
activated by the provided key.
MICROJIB A
Both ON indicates the JIB arm is completely closed.
MICROJIB B
PEDALE ON position indicates the pedal within the basket is
pressed. (only pedal version)
EM BASK. A
Both ON indicates the emergency STOP (of the remote
control) within the basket isn't pressed
EM BASK. B
POSM 1 A
Both ON indicates the stabilizer 1 is in stabilization posi-
tion.
POSM 1 B
POSM 2 A
Both ON indicates the stabilizer 2 is in stabilization posi-
tion.
POSM 2 B
POSM 3A
Both ON indicates the stabilizer 3 is in stabilization posi-
tion.
POSM 3B
POSM 4A
Both ON indicates the stabilizer 4 is in stabilization posi-
tion.
POSM 4B
R.C. PLATFORM ON position indicates the remote control is in its mount.
(in the platform).
INCLIN. X Indicates the inclination of X axis in tenths of a degree.
INCLIN. Y Indicates the inclination of Y axis in tenths of a degree.
LOAD Indicates the weight in the platform in pounds.
POS. 1E2 I nd ic at es 1 ° an d 2 ° a rm cylinder st roke in te nths of a m il-
limeter.
POS. 3 Indicates 3° arm cylinder stroke in tenths of a millimeter.
ROTATION A Indicates the angular position of the aerial part in
degrees (180° - aligned photocells).
MOTOR RPM Indicates the engine speed.
CURRENT A Indicates the power to proportional valve.
CURRENT B Indicates the power to proportional valve.
CURRENT C Indicates the power to proportional valve.
TEMPERAT. Indicates the temperature measured by the electrical
probe.
SUPPLY (V) Indicate the voltage (In volts).