Operator Manual Owner manual

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3128791 – JLG Lift – 6-21
6.6 LITHIUM-ION MACHINE - MAINTAINANCE
Cleaning the Machine
WHEN WASHING THE MACHINE, THE MAIN POWER SWITCH MUST
BE DISENGAGED, THE KEY REMOVED AND THE EMERGENCY
STOP BUTTON PRESSED.
Washing the outside of the machine;
Never use flammable liquids. Adopt the above safety
measures to prevent sparks due to short-circuits.
If washing the track with a cleaning solution, carefully
cover all the vital parts and above all the electrical com-
ponents. Follow the instructions provided by the manu-
facturer of the cleaning solution.
Clean the machine using only water-soluble detergents.
The more often the machine is cleaned, the more it will
need to be re-greased (see lubrication chart).
Do not wet the electric motors and the other electrical
components directly.
Do not aim the spray directly onto decals and rating
plates.
Cleaning the electrical system;
NEVER CLEAN THE INVERTER OR THE ELECTRIC MOTOR WITH
WATER, AS THIS MAY CAUSE DAMAGE TO THE ELECTRICAL SYS-
TEM.
ONLY USE DRY DETERGENTS, IN ACCORDANCE WITH THE MANU-
FACTURERS’ INSTRUCTIONS. NEVER REMOVE COVERS, GUARDS
AND THE LIKE.
Clean the electrical system using a dry, non-metallic
brush and low pressure air.
After cleaning
Dry the machine carefully before starting it again (for
example using compressed air).
IF, DESPITE ALL THE PRECAUTIONS, MOISTURE HAS PENE-
TRATED INTO THE ELECTRIC MOTOR OR OTHER PARTS OF THE
ELECTRIC SYSTEM, THESE MUST BE DRIED USING COMPRESSED
AIR TO AVOID THE RISK OF SHORT CIRCUITS.