Operator Manual User guide

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-8 – JLG Lift – 3121637
Figure 6-2. Component Maintenance Intervals - with Honda Engine
HONDA GAS ENGINE
PART INTERVENTION
BEFORE
STARTING
AS
NEEDED
INTERVAL (HOURS)
10 50
100
250
500
1000
DRY AIR FILTER
CHECK, CLEAN
CHANGE
ENGINE OIL
CHECK LEVEL
CHANGE
*
OIL SUMP
CLEAN
FUEL TANK AND NET
CLEAN
HYDRAULIC OIL
CHECK LEVEL
CHANGE
HYDRAULIC OIL
FILTER
CHANGE CARTRIDGE
*
ARTICULATED JOINT
POINTS
GREASE
*
BATTERY
CHECK ELECTROLYTE
LEVEL
REDUCTION GEAR
OIL
CHECK LEVEL
CHANGE
*
MACHINE
GENERAL PERIODICAL
CHECKS
*
EXTENSION ARM
INTERNAL SLIDING
RING
CHECK WEAR
CHANGE
TURNTABLE BOLT
TIGHTENING
CHECK
*
*
First time service interval
then per chart thereafter.
**
Every 3 months or
1000 hrs of operation.
***
Every 5 years or
2000 hrs of operation.
#
Check every year.
If the torque is not
correct replace the nuts
with two new nuts of
the same specification.
Install dry without
using oil or grease to
specified torque.
PLATFORM MOUNT
PIN NUTS
#
CHECK TORQUE
200 Nm