Operator's Manual

repeaters enabled and additional
non-base station radios.
StarFire is a trademark of Deere & Company
HC94949,0000B17-19-10MAY17
Diagnostic LEDs
Use diagnostic LEDs on RTK radio and in-line amplier
to determine working state of RTK Radio 450 system.
RTK Radio 450 LEDs
PC13863—UN—13JUL11
A—LED Window
After radio is powered, three LEDs in window (A) display
working state of radio.
NOTE: RTK Radio 450 allows up to 6 min. for machine
and base station to connect.
Radio enters conguration mode when parameters are
being read or set, and when diagnostics are being
retrieved. Radio does not transmit or receive
communications while in congure mode.
Operation Base Station Conguration
Searching Base station does not search.
Connected and Transmitting Solid Red
Fast Blinking Red
Off
Conguring Solid Green
Solid Green
Solid Green
Radio LEDs (Base Station)
Operation Machine Conguration
Searching Solid Red
Off
Slow Blinking Red
Connected and Transmitting Solid Green
Off
Solid Red
Conguring Solid Green
Solid Green
Solid Green
Radio LEDs (Machine)
Operation Repeater Conguration
Searching Solid Red
Off
Slow Blinking Red
Connected and Transmitting Solid Green
Fast Blinking Red
Solid Red
Conguring Solid Green
Solid Green
Solid Green
Radio LEDs (Repeater)
Amplier LEDs
PUPC000031—UN—07DEC09
LEDs are located on side of amplier.
Power LED indicates amplier has DC power.
TX LED indicates RF signal is being actively amplied
and transmitted. Blinking light indicates normal function.
O/T LED indicates unit has exceeded its internal
temperature limits. When light is on, unit ceases
amplication and waits to cool down to prevent
permanent damage.
VSWR LED indicates faulty antenna path. When light is
on, unit ceases amplication. Output power is prevented
Troubleshooting