JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION M159605 J9 Push Spreader LP21785, LP22875 OMM159605 J9 OMM159605 J9 OPERATOR’S MANUAL Original Instruction All information, illustrations and specifications in this manual are based on the latest information at the time of publication. The right is reserved to make changes at any time without notice. COPYRIGHT© 2009 Deere & Co.
INTRODUCTION Introduction Assembly Using Your Operator’s Manual Identify Parts Read this entire operator’s manual, especially the safety information, before operating. Qty. Description This manual is an important part of your machine. Keep all manuals in a convenient location so they can be accessed easily. 1 Hopper Assembly Use the safety and operating information in this manual to operate the machine safely and correctly.
ASSEMBLY bracket assembly (C) through frame tubes and arm assembly with two M6x45 bolts (B) and M6 locknuts (A). E O G N F K MX42991 2. Tilt arm assembly (E), and insert rod (F) into flow control handle (G). J H MX44032 4. Tighten nuts and bolts (H) on both sides of spreader. D E D C A B MX42992 3. Insert arm assembly (E) between frame tubes (D).
STORAGE Install Deflector (Optional) I NOTE: Deflector must be installed on the left side of hopper. D F G C E L G B A M MX44037 1. Rotate spreader onto its right side and remove two M6x40 screws (A) from the left side of hopper frame (B). 2. Install deflector bracket (C) with two new M6x45 screws. MX44033 5. Push the the flow control handle (G) downward (I) to the fully closed position, close the shut off plate under the hopper, and hand tighten bottom nut (J) on linkage rod until snug.
OPERATING Operating the Spreader The flow control handle assembly operates the flow control plate. The flow control assembly is marked 0 (closed) to 30 (fully open). The position selected determines the amount of material to be broadcast. The higher the number, the heavier the application of material. NOTE: The edge of the wingnut is the marker, and not the center of wingnut. When the flow control handle is opened fully, the edge of the wingnut should be on the determined setting mark.
OPERATING Determining Application Flow Setting 3 mph/264 fpm is recommended for this spreader. 1. Check material manufacturer’s container for recommended application flow and setting. • Always close the flow control handle before filling the hopper. 2. When no setting is recommended by the material manufacturer, use application flow setting charts in SPECIFICATIONS when spreading grass seed or when material size and desired coverage is known. 3.
SERVICE and dry. • Never allow material to remain in hopper for extended periods of time. • Should rust develop, sand lightly and then paint area with enamel. • Periodically check all fasteners for tightness. • Rinse/dry inside and outside of spreader after each use. Move flow control as you rinse, to avoid build up of material. Calibrating Shut Off Plate MX40451 B 2. Spread header strips at each end of area. This allows a turn-around area to align spreader for next pass. 3.
SPECIFICATIONS lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb 3.2 13.5 Bayer Lawn Fertilizer Plus Weed Control II 30-3-4 3.8 13.5 Bayer Season Long Grub Control Specifications 2.9 12.0 Bayer Season Long Grub Control 50 lb Spreader 3.6 13.5 Bayer Lawn Starter Fertilizer 20-27-5 3.2 13.5 Bayer Lawn Fertilizer Plus Crabgrass Preventer 30-3-4 3 13.5 Eliminator Ant, Flea, and Tick Killer Granules 2.5 12.0 Eliminator Ant, Flea, and Tick Killer Granules 2 12.
SPECIFICATIONS lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb 4.2 16.0 Lesco Fertilizer 18-0-18 (Fall/Winter) 6.5 13.5 Parkers Super Soilife Lawn and Garden Fertilizer 16-4-8 5.9 16.0 Lesco Fertilizer 17-17-17 (All Purpose) 3.6 15.0 Pennington Lawn Starter Fertilizer 18-24-6 10 18.0 6.3 16.0 Lesco Fertilizer 16-4-8 Pennington Master Turf High Traffic Lawn Seed Mixture 6.7 16.
SPECIFICATIONS lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb 5.4 15.0 Sam’s Choice Crabgrass Preventer 30-3-4 3.2 17.0 Scotts Turf Builder 28-3-3 3 12.0 Sam’s Choice Insect Control Plus Fertilizer 28-4-6 5 20.0 Scotts Turf Builder 28-3-3 2.5 13.5 Scotts Weed and Feed 33-3-3 3.2 13.5 Sam’s Choice Lawn Food 29-3-4 25 25.0 Scotts Pro Turf Fungicide VII 8-2-1 6 16.
SPECIFICATIONS lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb lbs/1000 square feet Flow Control Setting at 3 mpha Materialsb 4.5 19.5 Scotts Pro Turf Fertilizer Plus Preemergent Weed Control 22-4-4 3.6 13.5 Vigoro Starter Fertilizer 3.2 13.5 Vigoro Turf Fertilizer 29-3-4 4.9 20.0 Scotts Pro Turf Fertilizer Plus Preemergent Weed Control 22-4-4 3 12.0 Vigoro Ultra Turf Winterizer 22-3-14 3.2 13.5 Vigoro Weed and Feed 4 16.
GETTING QUALITY SERVICE lbs/1000 square feet Flow Control Setting 4 22 5 24 Getting Quality Service John Deere Quality Continues with Quality Service John Deere provides a process to handle your questions or problems, should they arise, to ensure that product quality continues with quality parts and service support. Follow the steps below to get answers to any questions you may have about your product. 1. Refer to your attachment and machine operator manuals. 2.