Owner manual

30
LEAKAGE CHECKPOINTS
Neverusethiswaterheaterunlessitiscompletelylledwithwater.
Topreventdamagetothetank,thetankmustbelledwithwater.
Watermustowfromthehotwaterfaucetbeforeturning“ON”gas
tothewaterheater.
A *Condensationmaybeseenonpipesinhumidweatherorpipe
connectionsmaybeleaking.
B.*Theanoderodttingmaybeleaking.
C.Smallamountsofwaterfromtemperature-pressurereliefvalve
maybeduetothermalexpansionorhighwaterpressureinyour
area.
D.*The temperature-pressurerelief valve maybe leakingat the
tanktting.
E.Waterfromadrainvalvemaybeduetothevalvebeingslightly
opened.
F.*Thedrainvalvemaybeleakingatthetanktting.
G. Combustion products contain water vapor which can
condenseonthecoolersurfacesofthetank.Dropletsform
anddripontotheburnerorrunonthefloor.Thisiscommon
atthetimeofstart-upafterinstallationandwhenincoming
wateriscold.
H.Water inthe water heater bottom or on the floor may be
from condensation, loose connections, or the relief valve.
DONOTreplacethewaterheateruntilafullinspectionof
allpossiblewatersourcesismadeandnecessarycorrective
stepstaken.
Leakage from other appliances, water lines, or groundseepage
shouldalsobechecked.
* To check where threaded portion enters tank, insert cotton
swabbetweenjacketopeningandtting.Ifcottoniswet,follow
“Draining”instructionsinthe“PeriodicMaintenance”sectionand
thenremovetting.Putpipedopeorteontapeonthethreads
andreplace.ThenfollowFillingtheWaterHeater”instructions
inthe“InstallingtheNewWaterHeater”section.
SERVICE
Ifaconditionpersistsoryouareuncertainabouttheoperationof
thewaterheatercontactaserviceagency.
Usethisguidetochecka“Leaking”waterheater.Manysuspected
“Leakers”arenotleakingtanks.Oftenthesourceofthewatercan
befoundandcorrected.
Ifyouarenotthoroughlyfamiliarwithgascodes,yourwaterheater,
andsafetypractices,contactyourgassupplierorqualiedinstaller
tocheckthewaterheater.
Readthismanualrst.Thenbeforecheckingthewaterheatermake
surethegassupplyhasbeenturned“OFF”,andneverturnthegas
“ON”beforethetankiscompletelyfullofwater.
B
D
C
F
G
E