1
. Attach the hose connector (No. 7) to the discharge side of the electric pump.
2. To the inlet side of the electric pump attach the 1/2’ hose barb (No. 6).
3. Install the hose pump to the base plate as shown in Figure 1 using the four (4) 1/4” nuts and bolts provided.
4. Attach one end of the 1/2” x 8” drain hose (No. 4) to the 3/8” barbed fitting on the drain body. Secure it with a hose
clamp.
5. Attach the other end of the 1/2” x 8” drain hose to the barbed fitting on the inlet side of the pump - securing with a
hose clamp.
6. Install one end of the 1/2” x 10’ (No. 3) drain hose to the discharge side of the pump.
7. On the opposite end of the discharge hose attach the 1/2” ball valve.
If the pump kit was purchased with the drain - proceed to Step 7 of the oil drain assembly instructions.
PARTS LIST
Item No. Description Qty.
1. Electric Pump 1
2. Pump Mounting Hardware 4
3. Discharge Hose 1/2” x 10’ 1
4. Drain Hose 1/2” x 8” 1
Item No. Description Qty.
5. Hose Clamp 2
6. Hose Barb Fitting 1/2” x 3/8” 1
7. Hose To Pipe Connector 1/2” 1
8 Ball Valve 1/2” (Not Shown) 1
1.
4.
2.
7.
3.
6.
5.
IMPORTANT - Always keep 1/2’ ball valve on the end of the discharge hose closed until you are ready to empty the tank.
Electric Pump is not self lubricating. DO NOT RUN PUMP DRY!
To Empty The Drain -
Position the drain next to the used fluid container.
Put discharge hose into the container and open the 1/2” ball valve.
Plug the electric pump into a 110v outlet to start
When empty, unplug the pump and close the ball valve.
When transporting the drain keep the electric cord and discharge hose attached to the handle using the brackets provided on the
handle.