PRODUCT DATA SHEET
AP
FOIL-FACED
PERFORMANCE ADVANTAGES
Thermal Insulation: inch for inch, polyiso
has one of the highest energy ef ciencies.
R-values for AP Foil-Faced Foam Sheathing
are shown in Table 1, and physical properties
are shown in Table 2 (see reverse). R means
resistance to heat fl ow. The higher the
R-value, the greater the insulating power.
Water-Resistive Barrier: when properly
installed as part of a Johns Manville Wall
System, AP Foil-Faced Foam Sheathing meets
the ICC-ES AC71 acceptance criteria for foam
plastic sheathing used as a water-resistive
barrier. Please see the installation guide for
qualifying assemblies and detailed instructions.
Vapor Barrier: at a minimum thickness
of one inch, AP Foil-Faced Foam Sheathing
has a vapor permeance of 0.05 perms and
qualifi es as a Class I vapor retarder.
Air Barrier: when properly installed
as part of a Johns Manville Wall System,
AP Foil-Faced Foam Sheathing meets the
Air Barrier Association of America boardstock
criteria for materials and assemblies. Please
see installation guide for qualifying assemblies
and detailed instructions.
Noncorrosive: does not accelerate
corrosion of pipes, wiring or metal studs.
Lightweight: easy to handle, can be cut with
a utility knife or saw.
ENERGY, QUALITY & ENVIRONMENT
DESCRIPTION
Johns Manville AP
Foil-Faced Foam Sheathing board consists of a uniform closed-cell
polyisocyanurate foam core bonded on each side to a foil facer. One side has a refl ective foil
facer and the other side has a white non-refl ective foil facer to suit your building needs.
Polyiso provides one of the highest R-values per inch of any rigid insulation (R-6.0 at
1 inch). Furthermore, when properly installed, AP Foil-Faced Foam Sheathing functions
as a water-resistive barrier, vapor barrier and air barrier, eliminating the need to install
additional components.
AP Foil-Faced Foam Sheathing is produced with an EPA-compliant hydrocarbon-based blowing
agent that has zero Ozone Depletion Potential (ODP) and virtually no Global Warming Potential
(GWP); it also meets both CFC- and HCFC-free specifi cation requirements. Polyiso is one of
North America’s most widely used insulation products and has been cited by the EPA for its
responsible impact on the environment.
AP Foil-Faced Foam Sheathing provides exceptional heat, moisture and air control to protect your
building’s exterior wall assembly.
INSTALLATION
AP Foil-Faced Foam Sheathing is lightweight and can be easily cut with a utility knife or saw.
Use maximum board lengths to minimize the number of joints. Vertical joints should be staggered.
Butt joints should be centered over framing. To create a water-resistive barrier or an air barrier,
treat seams and penetrations as instructed in the installation guide and in accordance with
manufacturer’s guidelines. Once installed, AP Foil-Faced Foam Sheathing may be left exposed
for up to 60 days. Consult your local building department for code requirements.
COMPLIANCES
• ASTM C1289 Type 1, Class 1
• CAN/ULC S704, Type 1, Class 1
• ICC-ES Evaluation Report ESR-3398
• Canadian Construction Materials Centre 13104-L
Air Barrier Association of America Evaluated Air Barrier Material,
Assembly & Water Resistive Barrier
• International Building Code
• International Residential Code
• International Energy Conservation Code
• ENERGY STAR
• ASHRAE 90.1
• California State Insulation Quality Standards
PERFORMANCE STANDARDS
ASTM C1289, Standard Specifi cation for Faced Rigid Cellular Polyisocyanurate Thermal
Insulation Board
CAN/ULC-S704, Standard for Thermal Insulation, Polyurethane and Polyisocyanurate,
Boards, Faced
• ASTM E84, Test for Surface Burning Characteristics of Building Materials
CAN/ULC S102, Standard Method of Test for Surface Burning Characteristics of Building
Materials and Assemblies
• NFPA 259, Standard Test Method for Potential Heat of Building Materials
NFPA 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of
Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
• AC 71, Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water-Resistive Barriers
ASTM E331, Standard Test Method for Water Penetration of Exterior Windows, Skylights,
Doors, and Curtain Walls by Uniform Static Air Pressure Difference
• AATCC Test Method 127, Water Resistance: Hydro Static Pressure Test
ASTM E1233, Standard Test Method for Structural Performance of Exterior Windows, Doors,
Skylights, and Curtain Walls by Cyclic Air Pressure Differential
• ASTM E2178, Standard Test Method for Air Permeance of Building Materials
• ASTM E2357, Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
AVAILABILITY
AP Foil-Faced Foam Sheathing is available in the sizes shown in Table 1 (see reverse).
For additional information or special size inquiries, please consult a sales representative
at 800-654-3103.
Polyisocyanurate Foam Sheathing
Continuous Insulation