Product Overview

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Product
Bulletin
5
Servicing Procedure for Coalescing Filters
All coalescing filters are equipped with an automatic
drain from which accumulations of entrapped liquids
are automatically blown out. The filter element should
be replaced when the leaving air pressure gauge
(mounted on the PRV station charcoal filter head)
indicates less than 50 psig (350 kPa) the differential
pressure between the leaving and input gauges is
15 psi (105 kPa) or more, or after one year of service—
whichever occurs first.
Table 5: Repair Parts
Description Code Number
Coalescing Filter Elements 10 scfm (4.7 l/s) A-4110-604
20 scfm (9.4 l/s) A-4000-604
40 scfm (18.9 l/s) A-4000-605
Charcoal Filter Elements 10 scfm (4.7 l/s) A-4000-632
20 scfm (9.4 l/s) A-4000-633
Filter Auto-Drain Kit (All Coalescing Filters) A-4000-6010
A-4110-604
(10 scfm)
A-4000-604
(20 scfm)
A-4000-605
(40 scfm)
Figure 13: Coalescing Filter Elements
A-4000-633
(20 scfm)
A-4000-632
(10 scfm)