Overview of Primary Product
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc.
www.johnsoncontrols.com
T-4000-605 (Beige) and T-4000-630 (White)
Universal Conversion Kits for Pneumatic Room Instruments
Description
The T-4000-605 (Beige) and T-4000-630
(White) Universal Conversion Kits provide all
the parts necessary to remodel existing room
installations, both Johnson Controls and non-
Johnson Controls. Both of these kits can be
applied to existing instrument installations with
exposed or concealed tubing.
Refer to T-4000-605 (Beige) and T-4000-630
(White) Universal Conversion Kits for
Pneumatic Room Instruments Technical
bulletin (LIT-7171085X) for additional
important product information.
Features
• includes adaptor cover/subplate with:
- cover plate with room instrument
mounting bracket
- two #6 x 3/8 in. pan-head, self-tapping
screws
- subplate and two #6-32 x 5/8 in.
pan-head taptite screws
• terminal connector and tubing with:
- terminal connector (three-tube with angle
terminals and O-rings assembled)
- three 8 in. lengths of 5/32 in. O.D. (black)
polyethylene tubing with anti-kink springs
attached
- one 8 in. length of 5/32 in. O.D. (amber)
polyurethane tubing with anti-kink spring
- one 9 in. length of 1/4 in. O.D. (blue)
polyurethane tubing with anti-kink spring
• T-400 air fittings with:
- supply terminal-angle fitting with integral
filter
- two control terminal-angle fittings with
integral filters
- two gaskets
- two gasket plates
- four mounting screws
• adjustable pipehead with:
- adaptor plate
- five #8 flat round washers
- three flat round washers gaskets
• tube couplings and clamps with:
- three 5/32 x 5/32 in. tubing couplers
- three 5/32 x 1/4 in. tubing couplers
- three flat round gaskets
• mounting hardware with:
- two #4-40 x 1-5/8 in. pan-head machine
screws
- two #5-40 x 3/4 in. studs
- four #5-40 hex nuts
- two # 5-40 x 1-1/4 in. pan-head machine
screws
- two #6 x 3/8 in. pan-head self-tapping
screws
- two #6-32 x 7/16 x 1-1/4 in. and 2 in.
pan-head machine screws
- two #6 x 1-3/4 in. pan-head self-tapping
screws
- two #6 star washers
- one #8 x 1-1/2 in. pan-head self-tapping
screw
- two #8-32 x 1-3/4 in. pan-head machine
screws
- two #10-24 x 1-1/2 in. pan-head machine
screws
- two #10-24 x 1-1/2 in. pan-head machine
screws
- two #10 star washers
- installation instructions 24-1855-5
Applications
The following tables list all of the known Johnson Controls conversions.
Pipehead, Gasket, and Adapter Arrangements (Part 1 of 2)
Style
Basic Pipehead
1
Description Gasket Replacement Pipehead Adaptor
I Single Size
Pipehead,
Two-Pipe
IIa Single Size
Pipehead,
One-Pipe
(Non-Relay)
IIb Single Size
Pipehead,
Two-Pipe with
Integral Restrictor for
Non-Relay
Controllers
Contact Branch Office for Customized Conversion Possibilities.
III Dual Size Pipehead
Two-Pipe (Heating-
Cooling or Dual
Tem p)
S
C
S
C
S
S
Not Used
S
C
S C
Close Pin
Valve
S
C
Code No. LIT-1921720
Issued January 15, 2008