Overview of Primary Product

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2011 Johnson Controls, Inc.
www.johnsoncontrols.com
Universal Conversion Kits for Pneumatic Room Instruments (Continued)
lV Dual Size Pipehead,
Three-Pipe
(Day-Night with
Switchline)
V Dual Size Pipehead,
Three-Pipe
(Submaster)
VI Dual Size Pipehead,
Three-Pipe
(Two-Single
Controllers or
Single Controller plus
Two-Position Relay)
This special pipehead can be converted several ways depending on the
controller to be used and the heating system to be converted. For example:
a) Use T-4002 with Control Air to C1 only or to both C1 and C2.
(A 5/32 in. Brass Tee, F-700-83, is Required if both C1 and C2 are used.)
b) Use T-4516 with the Third Terminal Connected to C2.
c) Use T-4003 with the Third Terminal Connected to C2.
VII Triple Size Pipehead,
Three-Pipe
(Or More)
Contact Branch Office for Customized Conversion Possibilities.
1. S = Main Supply Air Lines P = Pilot Air Line C, C1, C2 = Control 33 (Branch) Air Lines SW = Switch Air Line
Pipehead, Gasket, and Adapter Arrangements (Part 2 of 2)
Style
Basic Pipehead
1
Description Gasket Replacement Pipehead Adaptor
S C
Sw
Close Pin
Valve
S
C
Not Used
Sw to Third
Terminal
S C
P
S
C
Not Used
P to Third
Terminal
S
C1
C2
Johnson Controls Conversions (Part 1 of 2)
Model Pipehead
Style
Recommended Conversion
(Using The T-4000-605 or T-4000-630 Kit)
T-315 V T-4003
T-400 I T-4002
T-401 I T-4002
T-402 I T-4002 and Two-Position Air Switching Device
T-403 I T-4002
T-405 III T-4506
T-408 I No Direct Replacement
1
T-411 V
T-418 III
T-423 III T-4756
T-425 I T-4002 and Two-Position Air Switching Device
T-431 VII No Direct Replacement
1
T-432 III T-4756
T-435 VII No Direct Replacement
1
T-441 IIa T-4100
T-441 IIb No Direct Replacement
1
T-445 IIb No Direct Replacement
1
T-460 III T-4506 With Manual Index Switch
T-461 III
T-462 III T-4506 and Two-Position Air Switching Device
T-465 IV T-4516
T-1210 I T-5002
H-101 V No Direct Replacement
1
H-102 I H-4100
H-103
H-104 I H-4100 and Two-Position Air Switching Device
H-105 I H-4100
H-107
H-1210 I H-5100
1. Contact branch office for custom conversion possibility.
Johnson Controls Conversions (Part 2 of 2)
Model Pipehead
Style
Recommended Conversion
(Using The T-4000-605 or T-4000-630 Kit)
Non-Johnson Controls Conversions
The T-4000-605 (Beige) and T-4000-630 (White) Universal Conversion Kits are designed to convert existing installations including:
Converts the Following Non-Johnson Controls Thermostats:
Barber-Colman “TK” Series Wallbox and Mortar Joint Powers TH180 Wallbox and Drywall Mounting
Honeywell TO900 or TP900 Series Wallbox Robertshaw T-15 (Metal) Early Wallbox and Mortar Joint
Honeywell TO910 or TP910 Series Wallbox and Mortar Joint Robertshaw T-15 Later Wallbox and Mortar Joint
Honeywell TP970 Series Shallow and Deep Wallboxes Robertshaw T-18 (Plastic) Drywall Mounting
Powers “D” Wallbox and Ground Plate Draeger (ITT/Essen/Johnson Controls) Wallbox
Powers T-21 Ground Plate, Wallbox, and Mortar Joint UPC