Operator's Manual
Table Of Contents
- Table of Contents
- 1 — Introduction
- 2 — Warnings, Cautions, and Other Residual Risks
- 3 — System Components
- 4 — Surgery Start Up
- 5 — Surgeon Settings
- 6 — Program Settings
- 7 — System Configuration
- Setting the Maximum IV Pole Height
- Testing the IV Pole
- Event Log
- Wireless Foot Pedal Setup
- VERITAS Remote Control Setup
- System Versions
- System Self Test
- Language Selection
- Surgical Media Center (SMC) (Optional)
- Set System Date and Time
- Set Units of Measure for Vacuum
- Service Interval
- Import/Export Database
- Backup All
- Print to File
- Restore Database
- Restore All
- Delete a Backup Database
- 8 — Symbol Definitions
- 9 — Care and Cleaning
- 10 — Error Messages, Troubleshooting, and Diagnostics
- 11 — Warranty and Maintenance
- 12 — Specifications
- Physical Specifications
- Environmental Specifications
- Electrical Specifications
- Electromagnetic Compatibility
- RF Wireless Technology
- Bluetooth Characteristics
- Phacoemulsification Specifications
- Irrigation and Aspiration Specifications
- Vitrectomy Specifications
- Diathermy Specifications
- Diathermy Power Graphs
- Diathermy Power versus Load Impedance
- Phaco Power Graphs
- Phaco Tip Velocity
- Bottle Height Pressure
- 13 — Accessories and Parts Reordering
- Index
Bluetooth Characteristics Z370584 Rev. C
12-18
Specifications
Table 12.13 – RF Transmit Section
Parameter Test Conditions Min
Typ
Max Unit
Output power Delivered to a single-ended 50-Ω load through a
balun using maximum recommended output power
setting
4dBM
Delivered to a single-ended 50-Ω load through a
balun using minimum recommended output power
setting
-20
Programmable
output power
range
Delivered to a single-ended 50-Ω load through a
balun
24 dB
Spurious
emissions
Conducted measurement with a 50-Ω single-ended
load. Complies with EN 300 328, EN 300 440 class 2,
FCC CFR47, Part 15 and ARIB STD-T-66
(1)
-41 dBm
Current
consumption
TX mode, -23-dBM output power, no peripherals
active, low MCU activity, MCU at 250 kHz
21.1 mA
TX mode, -6-dBM output power, no peripherals
active, low MCU activity, MCU at 250 kHz
23.8
TX mode, 0-dBM output power, no peripherals
active, low MCU activity, MCU at 250 kHz
27
TX mode, 4-dBM output power, no peripherals
active, low MCU activity, MCU at 250 kHz
31.6
Optimum load
impedance
Differential impedance as seen from the RF port
(RF_P and RF_N) toward the antenna
70 + j30 Ω
(1) Designs with antenna connectors that require conducted ETSI compliance at 64 MHz should insert an
LC resonator in front of the antenna connector. Use a 1.6-nH inductor in parallel with a 1.8-pF capacitor.