Operator's Manual
Table Of Contents
- Table of Contents
- 1 — Introduction
- 2 — Warnings, Cautions, and Other Residual Risks
- 3 — System Components
- 4 — Surgery Start Up
- 5 — Surgeon Settings
- 6 — Program Settings
- 7 — System Configuration
- Setting the Maximum IV Pole Height
- Testing the IV Pole
- Event Log
- Wireless Foot Pedal Setup
- VERITAS Remote Control Setup
- System Versions
- System Self Test
- Language Selection
- Surgical Media Center (SMC) (Optional)
- Set System Date and Time
- Set Units of Measure for Vacuum
- Service Interval
- Import/Export Database
- Backup All
- Print to File
- Restore Database
- Restore All
- Delete a Backup Database
- 8 — Symbol Definitions
- 9 — Care and Cleaning
- 10 — Error Messages, Troubleshooting, and Diagnostics
- 11 — Warranty and Maintenance
- 12 — Specifications
- Physical Specifications
- Environmental Specifications
- Electrical Specifications
- Electromagnetic Compatibility
- RF Wireless Technology
- Bluetooth Characteristics
- Phacoemulsification Specifications
- Irrigation and Aspiration Specifications
- Vitrectomy Specifications
- Diathermy Specifications
- Diathermy Power Graphs
- Diathermy Power versus Load Impedance
- Phaco Power Graphs
- Phaco Tip Velocity
- Bottle Height Pressure
- 13 — Accessories and Parts Reordering
- Index
Tubing Packs Z370584 Rev. C
3-4
System Components
Tubing Packs
Each surgical procedure requires a disposable tubing pack. The FUSION
™
Dual Pump Tubing
Pack, VERITAS Advanced Infusion Tubing Pack, and the VERITAS Advanced Fluidics Tubing
Pack work with both the peristaltic pump and the Venturi pump. All the supported packs are
dual pump packs, so you can select either pump while you are in a surgical case.
The tubing pack contains the following components:
• A tubing pack with irrigation and aspiration tubing (administration set) with an atta
ched,
sealed drain bag
• Test chamber – to test and prime/tune the phaco handpiece
• Mayo tray drape – to cover the Mayo tray and arm
• Monitor drape – to cover the front of the touchscreen monitor
WARNING!
All tubing packs are single-use. Reusing a single-use device can cause bodily fluids
from one patient to enter the eye of another patient. This can lead to medical
conditions including: Toxic Anterior Segment Syndrome (TASS) or Chemosis,
Conjunctivitis Microbial, Endophthalmitis, Infectious Keratitis, Anterior Uveitis, and
Keratoconjunctivitis.
WARNING!
Use proper handling and disposal methods for biohazards when you dispose of the
tubing pack, Mayo tray drape, and monitor drape.