User guide

Digital Angle Locator
Model No. 40-6064
Instruction Manual
Congratulations on your choice of this Digital Angle Locator. We
suggest you read this instruction manual thoroughly before using the
instrument. Save this instruction manual for future use.
Features and Functions
Digitally displays angle
Angle measurements in degrees
Working range of angle measurement
0 to 222º
Automatic shut-off
Hold function to freeze measurement
Safety Instructions
Please read and understand all of the following
instructions, prior to using this tool.
Location of Parts/Components
Angle level arm
Battery
compartment
Vial for
horizontal
leveling
Vial for
vertical
leveling
Base arm
Hold Key
Miter key
On/Off key
Battery Installation
To open the battery cover, unscrew the
end cap then pull out
Insert the 9V battery paying attention to
the polarity, put back the end cap and
screws
Power on the instrument
Note:
Used (discharged) batteries are hazardous
waste and should be disposed of properly. Take
out the batteries if the instrument is not going
to be used for a long time.
Using the Product
On/Off Key
Power on and off the instrument by pressing
this key.
Hold Key
The angle readings change in accordance with
the change of the angle measurement. Press
the key to enter into the “hold” mode. The
measured angle reading will be held. Pressing
the key again will stop the “hold” mode and
measured value will change with the movement
of the angle level arm.
Miter Key
The key switches the measured angle and con-
verts it to the miter cut angle. This measure-
ment is the angle that needs to be set in the
miter saw to create the correct cut angle.
Automatic Shut-off
This instrument will shut-off automatically if no
operation is received within five minutes.
Measuring Angles
Position the angle level arm and the base arm
plane against the edges to be measured. The
displayed reading corresponds with the z angle
between the angle level arm and the base arm.
The displayed reading can be retained in the
display by pressing the HOLD key.
When the hold key is pressed, “HOLD” is
indicated in the display. The measured angle
reading will be held (even when the legs are
moved in relation to each other) until the HOLD
key is pressed again.
a work piece, pay attention that the angle level
arm and base don’t move. After pressing the
HOLD key, which store the measured angle, the
user can now activate the MITER key. By
pressing the miter key, the Angle Finder is tak-
ing the measured angle and
converting it to the correct
miter cut angle. This
measurement is the angle
that needs to be set in the
miter saw to create the
correct cut angle.
Transferring angle to miter angles
When directly projecting a measured angle onto
Technical Specifications
Working Range Angle 0º - 222º
Accuracy Angle ±0.5º (9mm/m)
Power Supply 1 9V battery
Battery Life Approx. battery life
50 hours
continuous use
Dimensions arm to 17.72"
arm length (450mm)
Weight 1.1 lbs
(0.5 Kg)
Working temperature 32ºF to 122ºF
(0ºC to -50ºC)
Automatic Shut-off After 5 min. approx.
Lifetime Warranty
Johnson Level & Tool warrants this product to be
free from defects in material or workmanship for
the normal life of this product. Product abuse
voids warranty. At its sole option, Johnson will
repair or replace this product if it fails to conform
to this warranty under normal use and service.
Johnson’s liability is expressly limited to the repair
or replacement of the defective product.
Note:
The user is responsible for the proper use and care of the
product.
For further assistance, or if you experience problems with
this product that are not addressed in this instruction
manual, please contact our Customer Service Department.
In the U.S., please call 800-563-8553.
In Canada, please call 800-346-6682.
Localizador de Ángulo Digital
Modelo N.° 40-6064
Manual de Instrucciones
Felicitaciones por elegir este Localizador de Ángulo Digital. Le
sugerimos que lea este manual de instrucciones cuidadosamente antes
de usar el instrumento. Guarde este manual de instrucciones para
poder consultarlo en el futuro.
Características y Funciones
Muestra el ángulo de forma digital
Mediciones de ángulos en grados
Rango operativo de medición angular de
0 a 222º
Apagado automático
Función de suspensión para congelar la
medición
Instrucciones de Seguridad
Lea y comprenda todas las instrucciones a
continuación, antes de utilizar esta herramienta.
Brazo del nivel de ángulo
Compartimento
de las baterías
El frasco para
nivelar horizontal
Ampolla para
nivelación
vertical
Brazo base
Botón de suspensión
Botón para
ingletes
Botón de
Encendido
y Apagado
Instalación de las Baterías
Para abrir la cubierta de las baterías,
desajuste la cubierta protectora para
extremos y luego extráigala
Inserte la batería de 9V prestando atención
a la polaridad, vuelva a colocar la cubierta
protectora para extremos y los tornillos
Encienda el instrumento
Nota:
Las baterías usadas (descargadas) son residuos
peligrosos y se deben desechar de forma ade-
cuada. Extraiga las baterías si el instrumento no
se va a utilizar durante un tiempo prolongado.
Cómo Utilizar el Producto
Botón de Encendido y Apagado
Para encender o apagar el instrumento presione
este botón.
Ubicación de las Piezas y
Componentes

Summary of content (2 pages)