Product Manual

26 ©2017 Johnson Level & Tool
10. Troubleshooting Guide
This section is designed to help you diagnose and troubleshoot
common problems that prevent the Laser Distance Meter from
working properly.
If the Laser Distance Meter returns an ERR code (display shows ERR
plus a number from 1 to 6), please
refer to Section 4
of this manual
for possible resolutions. If your Laser Distance Meter fails to operate
in any other way, please refer to the following troubleshooting guide
for some suggestions on how to diagnose the problem.
Symptom
Will not turn on
Possible Cause
Batteries missing or
depleted
Polarity reversed
Solution
Change the batteries
Check battery polarity
Turns off after a short
time
Batteries depleted Change the batteries
Flashing or beeping
Laser is beyond leveling
range
Laser is out of
calibration
Place on surface within
4° of level
Perform calibration
check; calibrate laser if
needed
2162i-3_Manuals 8/22/17 9:24 AM Page 26