Use and Care Manual

18
SERVICE AND ADJUSTMENTS
TO ADJUST CHUTE ROTATOR CABLE TENSION
(See Fig. 25)
1.  Adjust cable tension by loosening the jam nuts next to 
the turn buckle. 
2.  Grasp the short section and hold while turning the long 
section to lengthen the adjuster. 
3.  Adjust until cable is snug and tighten jam nuts.
AUGER PERFORMANCE AND CABLE ADJUSTMENT 
(See Fig. 25)
NOTE: If you do not feel comfortable making this adjustment 
yourself, please contact an authorized service center/
department.
Adjustments may be needed if the impeller and auger 
rotation is sluggish when engaging the auger control lever, 
or if the auger belt has been replaced.
To adjust the auger control cable:
1.    Adjust cable tension by loosening the jam nut, next to 
the turn buckle. 
2.   Grasp the short section and hold, while turning the 
long section to lengthen the adjuster. Rotate the center 
barrel one full revolution.
3.    Retest auger engagement. Repeat adjustment as 
needed until engagement is no longer sluggish.
4.     Have an assistant stand 10 feet in front of the machine, 
and on the opposite side that the chute is pointing. The 
assistant should observe the rotation of the auger and 
measure the time it takes for the auger to stop rotating 
after you release the lever. 
If the auger stops rotating after 5 seconds, readjust the cable 
by rotating the center barrel one full revolution, so that the 
adjuster is contracting. Retest the auger engagement and 
measure the stop time again.
If the auger stops rotating in less than 5 seconds, proceed 
to the next step.
5.  Tighten the jam nut on the auger cable.
NOTE: If the adjustment does not resolve the problem, 
replace the auger belt. See “To Replace Belts” in the Service 
& Adjustments section of this manual.
FIG. 25
CHUTE 
ROTATOR 
CABLES
ADJUSTER 
TURN BUCKLE
JAM NUT
AUGER 
CONTROL 
CABLE