User's Manual

DOC No: ZB7412-00A-DTS-R03
____________________________________________________________________________________
Copyright © JORJIN TECHNOLOGIES INC. 2017 27
http://WWW.JORJIN.COM.TW
4.22.
(5) Refer to SSI timing diagrams Figure 4-1, Figure 4-2, and Figure 4-3.
4.26. Switching Characteristics
Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
Parameter
Test Conditions
Min
Typ
Max
Units
WAKEUP AND TIMING
Idle Active
14
μs
Standby Active
151
μs
Shutdown Active
1015
μs
SYNCHRONOUS SERIAL INTERFACE (SSI)
(1)
S1 (TX only)
(2)
t
clk_per
(SSIClk period)
One-way communication to SLAVE
4
65024
system
clocks
S1(TX and RX)
(2)
t
clk_per
(SSIClk period)
Normal duplex operation
8
65024
S2
(2)
t
clk_high
(SSIClk high time)
0.5
t
clk_per
S3
(2)
tclk_low(SSIClk low time)
0.5
t
clk_per
(1) Device operating as MASTER. For SSI SLAVE operation, see Section 4.21.
(2) Refer to SSI timing diagrams Figure 4-1, Figure 4-2, and Figure 4-3.
Figure 4-1. SSI Timing for TI Frame Format (FRF = 01), Single Transfer Timing Measurement