User's Manual

84066_UM_ L-3 FFSVR_B 39
EPIRB Battery and the Hydrostatic Release Mechanism. Check the
presence of a firmly attached lanyard in good condition and that it
is neatly stowed and is not tied to the vessel or the mounting
bracket. If the L-3 FFSVR is the main EPIRB on board, these rules
must be followed:
Every 12th Month: Perform extended annual test according to
IMO’s MSC/Circ.1040 (Annual testing of 406 MHz satellite
EPIRBs) as required by SOLAS IV/15.9.This test can be carried
out by one of Jotron AS authorized representatives or any other
service provider in possession of a Tron UNIDEC, Tron DEC or
any other Cospas/Sarsat EPIRB tester/decoder.
The test ensures that the EPIRB is within its specifications and
complies with IMO and the COSPAS/SARSAT system.
Documented proof of test or Test Certificate containing test results
and EPIRB data issued by service provider must be kept onboard
for future inspections the next 12 months.
Every 2ndYear:
Hydrostatic Release Mechanism including Plastic Bolt on the Float
Free Brackets must be replaced.(Check expiry date on label).
Every 5thYear:
The EPIRB Battery must be replaced every 5th year, unless
otherwise instructed by the vessel flag state or local
authorities.(Check expiry date on label).