TR-8000 Operator and Installation Manual 53
8.3.1.3 Power connection
Table showing connection of main and backup power
See also figure Figure 8-10
Allowed voltage levels of the power supply to be connected with the transponder:
Minimum = 10.8 volt
Maximum = 31.2 volt
Recommended cable diameter: 2.5 – 4 mm
2
Connection
Function
P1
GND (Chassis)
P2
MAIN 0V
P3
MAIN 12 - 24 VDC
P4
GND (Chassis)
P5
BACKUP 0V
P6
BACKUP 12 – 24 VDC