Installation Manual Part 2
Table Of Contents
- 8 Installation
- 8.1 Mechanical Mounting
- 8.2 Cabling
- 8.3 Wiring and Connections
- 8.3.1 Transponder
- 8.3.1.1 Pictorial display of typical connections to the transponder
- 8.3.1.2 Label in transponder with connection tables
- 8.3.1.3 Power connection
- 8.3.1.4 Sensor connections
- 8.3.1.5 External display – ECDIS/Radar connections
- 8.3.1.6 Pilot / Aux. Display connection
- 8.3.1.7 Alarm Connection
- 8.3.1.8 Detailed description of connections, fuses, factory reset etc.
- 8.3.2 Display Unit:
- 8.3.1 Transponder
- 9 Initial configuration
- 10 Operation Instructions
TR-8000 Operator and Installation Manual 54
8.3.1.4 Sensor connections
Sensors like GPS, Gyro, Speed log etc may be connected to the 3 different sensor inputs in the
TR-8000 Transponder unit.
Recommended cable diameter: 0.25 - 2.5mm
2
The TR-8000 also offers a unique
feature of troubleshooting sensor problems
as it has a built in “Port monitor” which will
display all raw sensor data in the Display
Unit.
How to use this monitor, is described in
chapter 10.2.1.6
#
In/
Out
Type
Usage
Name
1
In
IEC61162-1
(RS422)
Sensor 1
RD1-B(+)
2
RD1 -GND (Iso Gnd)
3
In
RD1-A(-)
25
In
IEC61162-1
(RS422)
Sensor 2
RD6-B(+)
26
RD6-GND (Iso Gnd)
27
In
RD6-A(-)
28
In
IEC61162-1
(RS422)
Sensor 3
RD7-B(+)
29
RD7-GND (Iso Gnd)
30
In
RD7-A(-)