TR-8000 Operator and Installation Manual 56
8.3.1.6 Pilot / Aux. Display connection
This Port may be mandatory to be used with Pilot port connector (See picture below) on some kind
of vessels. Otherwise, this port may be used to connect a secondary display (Maybe ARPA radar, if
“External display” is connected to ECS/ECDIS)
This port is one of two options to connect a Pilot connector, as it is also possible to connect Pilot
port cable to the TR-8000 Display Unit, see chapters 8.3.2 and 10.2.1.3
Default speed on this port is 38400 baud.
#
In/Out
Type
Usage
Name
Connects to AMP
206486-1 Pin no:
16
In
IEC61162-2
(RS422)
Pilot / Aux
Display
RD4-B(+)
6
17
RD4-GND (Iso Gnd)
9
18
In
RD4-A(-)
5
19
Out
TD4-A(-)
1
20
TD4-GND (Iso Gnd)
21
Out
TD4-B(+)
4
Figure 8-15 AMP 206486-1 (Pilot
Plug) pinout
Figure 8-14 Pilot plug with cable