Installation Manual Part 2

TR-8000 Operator and Installation Manual 40
8.1.2 Display Unit
The display unit can be installed as desktop mounted, roof mounted or flush mounted in a panel.
Installation shall be near the conning position.
When selecting a mounting location for the Display Unit the following guidelines apply:
1. Do not mount the display unit were it can be directly exposed to seawater as corrosion
then may appear and cause leakage.
2. The unit must not be mounted near exhaust pipes and vents.
3. Even though the transponder is a robust unit, it is advised that it should be mounted were
shock and vibration are minimal.
4. Unit shall not be located near electromagnetic field generating equipment
5. Leave sufficient space at the back for connection to necessary cables.
6. Do not mount transponder unit too close to a magnetic compass :
Compass safe distance: Standard Compass: 30cm
Steering Compass: 14cm
8.1.2.1 Desktop Mounting
For detailed mechanical drawings, see chapter 14,”Outline Drawings
Figure 8-2 Desktop mounted Display Unit