Technical Manual

Table Of Contents
TR-8000 Technical manual 3-13
3.1.2.1 Electrical characteristics RS232
Min
Typ
Max
Unit
Input Resistance
3
5
7
kΩ
Input Voltage Range
-15
15
V
Input Threshold LOW
0.8
1.5
V
Input Threshold HIGH
1.8
2.4
V
Output Resistance
300
Ω
Output Voltage Swing
±5.0
±5.4
V
Output Short-Circuit Current
±32
±60
mA
3.1.2.2 Display connection
The display is interfaced over Ethernet by LAN8187, enabling data from 10 to 100Mbit/s. The circuit is
galvanically isolated by a transformer and isolated to ground by 2kV capacitors.
The interface is compliant with IEEE 802.3-2005 standards. The connector is a circular RJ45 connector,
Bulgin PX0833/E on the Transponder and PX0839/PC on the Display Unit.
The default IP address of the Transponder is 10.0.0.10 and
the default IP address of the Display Unit is 10.0.0.11.
3.1.2.3 Alarm relay
The Alarm relay is a mandatory normally open earth free relay contact, provided as an independent and
simple method for triggering an external alarm. The alarm relay is active in case of power off and is capable
of driving a 2A current. The relay is implemented as a FET-switch, using FDS3992 Dual N-Channel
PowerTrench® MOSFET. . The connector on the Transponder is 5mm Double Deck Terminal Strips from
WAGO (736-204).
Min
Typ.
Max
Unit
Voltage
48
V
Current
2
A
Resistance
124
mΩ