User's Manual

25
www.jotron.com www.jotron.com
85525_UM_60S/GPS_ J
2
1
Hold 15
sec.
Only 1
flash = OK
3
5.2 AUTOMATIC OPERATION - FLOAT FREE BRACKET FB-60
1. The Tron 60S/GPS will automatically release from the bracket, float to the
surface and start to transmit when the EPIRB, in its bracket is deployed into
water at a depth of app. 2-4 meters (6 - 13 feet).
2. Transmission will continue until the EPIRB is lifted out of the water, and dried
off. The transmission can also be stopped by placing the EPIRB in the
bracket.
5.3 TEST
To perform the self-test, the EPIRB has to be removed from the bracket.
FB-60 bracket: Release FB-60 top cover by removing the cotter pin.
1. Push and hold switch in TEST position for 15 seconds. Keep hands and other
objects away from the antenna.
2. Test passed after one single flash only!
3. Release the switch and put the EPIRB back into the bracket
WARNING
The EPIRB can drop
out of the FB-60
bracket when releasing
top cover
Release
the switch
after 15