Operation Manual

13
ENGLISH
For fastening Ø 80 / Ø100 fresh air intake tube (optional
equipment – item no. 51047509 / 51012164), see the manual
(item no. 10047508) accompanying the external air set. See
the installation instructions that follow with the external air set.
Attach the hose to the external air connector with a hose clip
to avoid using joints. The external air hose insulation ends
approx. 100 mm below the burn chamber.
Fig. 8
Then install the cover for outdoor air inlet underneath of the
oven.
Through the oor
Fig. 9
100
Use a heavy mallet and strike hard in the middle of the
knockout
Pull a exible hose through the oor and up to the air
intake connector.
Then attach the exible hose to the air intake connector
with a hose clamp
For fastening Ø80 / Ø100 fresh air intake tube (optional
equipment item no. 51047509 / 51012164), see the
manual (item no. 10047508) accompanying the external
air set. See the installation instructions that follow with
the external air set. Attach the hose to the external air
connector with a hose clip to avoid using joints. The
external air hose insulation ends approx. 100 mm below
the burn chamber.
4.4 Chimney and ue pipe
The replace must only be connected to a chimney and
ue pipe approved for solid fuel replaces with ue gas
temperatures as specied in «2.0 Technical Data».
Several solid fuel stoves can be connected to the same
chimney system if the chimney cross section is adequate.
NB: Look into the applicable rules and regulations to
nd out what is permitted. Even a good chimney can
function poorly if it is used incorrectly.
The cross-section of the chimney must be designed to t the
replace. Use «2.0 Technical Data» to calculate the correct
chimney cross-section.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the replace and the hole in the chimney. See g. 1 for
minimum dimensions.
Make sure that the ue pipe rises all the way up to the
chimney.
With a rear outlet, use a ue pipe bend with a sweep hatch
to allow sweeping.
Please note that it is extremely important for connections to
have a degree of exibility. This is to prevent any movement
in the installation leading to the formation of cracks.
For recommended chimney draught, see «2.0 Technical
Data». For ue pipe dimension see “2.0 Technical Data”.
NB: The chimney’s diameter must be at least just as big
as the ue pipe.
NB! The minimum recommended chimney length is 3.5 m
from the ue pipe insert. If the draught is too strong, a ue
pipe damper can be installed and used to reduce the draught.
Operation under different weather
conditions
The effect of the wind on the chimney may have a signicant
impact on how the stove reacts under different gust loads. It
may be necessary to adjust the air supply to achieve good
combustion.